Evidence map›Paper›PMID 37430394›Full record

ArticleClinical endoscopy2024

A novel fully covered metal stent for unresectable malignant distal biliary obstruction: results of a multicenter prospective study.

Arata Sakai, Atsuhiro Masuda, Takaaki Eguchi, Keisuke Furumatsu, Takao Iemoto, Shiei Yoshida, Yoshihiro Okabe, Kodai Yamanaka, Ikuya Miki, Saori Kakuyama and 6 more

Open access · goldAbstract read
In one paragraph

Article in Clinical endoscopy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors at 9 institutions in 1 country.

Arata SakaiDivision of Gastroenterology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.
Atsuhiro MasudaDivision of Gastroenterology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.
Takaaki EguchiDepartment of Gastroenterology and Hepatology, Osaka Saiseikai Nakatsu Hospital, Osaka, Japan.
Keisuke FurumatsuDepartment of Gastroenterology, Akashi Medical Center, Akashi, Japan.
Takao IemotoDepartment of Gastroenterology, Kita-Harima Medical Center, Ono, Japan.
Shiei YoshidaDepartment of Gastroenterology, Kobe Medical Center, Kobe, Japan.
Yoshihiro OkabeDepartment of Gastroenterology, Kakogawa Central City Hospital, Kakogawa, Japan.
Kodai YamanakaDivision of Gastroenterology, Konan Medical Center, Kobe, Japan.
Ikuya MikiDepartment of Gastroenterology, Hyogo Cancer Center, Akashi, Japan.
Saori KakuyamaDepartment of Gastroenterology, Takatsuki General Hospital, Takatsuki, Japan.
Yosuke YagiDepartment of Internal Medicine, Shiso Municipal Hospital, Shiso, Japan.
Daisuke ShirasakaDepartment of Gastroenterology, Kobe Red Cross Hospital, Kobe, Japan.
Shinya KohashiDivision of Gastroenterology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.
Takashi KobayashiDivision of Gastroenterology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.
Hideyuki ShiomiDivision of Gastroenterology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.
Yuzo KodamaDivision of Gastroenterology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.
Kobe University · JPAkashi Medical Center · JPHyogo Prefectural Cancer Center · JPJapanese Red Cross Kobe Hospital · JPKagawa Prefectural Central Hospital · JPKobe Medical Center · JPSaiseikai Nakatsu Hospital · JPTakatsuki General Hospital · JPTokyo-Kita Medical Center · JP

Funding

JSPS KAKENHI JP19K07938
6 · The paper itself

Abstract

BACKGROUND/

aimsEndoscopic self-expandable metal stent (SEMS) placement is currently the standard technique for treating unresectable malignant distal biliary obstructions (MDBO). Therefore, covered SEMS with longer stent patency and fewer migrations are required. This study aimed to assess the clinical performance of a novel, fully covered SEMS for unresectable MDBO.

methodsThis was a multicenter single-arm prospective study. The primary outcome was a non-obstruction rate at 6 months. The secondary outcomes were overall survival (OS), recurrent biliary obstruction (RBO), time to RBO (TRBO), technical and clinical success, and adverse events.

resultsA total of 73 patients were enrolled in this study. The non-obstruction rate at 6 months was 61%. The median OS and TRBO were 233 and 216 days, respectively. The technical and clinical success rates were 100% and 97%, respectively. Furthermore, the rate of occurrence of RBO and adverse events was 49% and 21%, respectively. The length of bile duct stenosis (<2.2 cm) was the only significant risk factor for stent migration.

conclusionsThe non-obstruction rate of a novel fully covered SEMS for MDBO is comparable to that reported earlier but shorter than expected. Short bile duct stenosis is a significant risk factor for stent migration.

Indexed as

Covered self-expandable metal stentMalignant distal biliary obstructionStent migration

Identifiers

PMID37430394
PMCPMC11133982
OpenAlexW4383683202

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.