Evidence map›Paper›PMID 37425071›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2023

Investigating Angiographic Injection Parameters for Cerebral Aneurysm Hemodynamic Characterization Using Patient-Specific Simulated Angiograms.

R White, A Shields, S V Nagesh, E Smith, J Davies, D R Bednarek, S Rudin, C Ionita, V Chivukula

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

R WhiteBiomedical Engineering, Florida Institute of Technology, State University of New York at Buffalo.
A ShieldsMedical Physics, State University of New York at Buffalo.
S V NageshMedical Physics, State University of New York at Buffalo.
E SmithBiomedical Engineering, Florida Institute of Technology, State University of New York at Buffalo.
J DaviesDepartment of Neurosurgery, State University of New York at Buffalo.
D R BednarekMedical Physics, State University of New York at Buffalo.
S RudinMedical Physics, State University of New York at Buffalo.
C IonitaMedical Physics, State University of New York at Buffalo.
V ChivukulaBiomedical Engineering, Florida Institute of Technology, State University of New York at Buffalo.
University at Buffalo, State University of New York · USFlorida Institute of Technology · US

Funding

High Speed Angiography at 1000 frames per secondR01EB030092 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2020 to 2023
$2.6M
NIBIB NIH HHS R01 EB030092
6 · The paper itself

Abstract

Cerebral aneurysm (CA) rupture is one of the major causes of hemorrhagic stroke. During endovascular therapy (ET), neurointerventionalists rely on qualitative image sequences and do not have access to crucial quantitative hemodynamic information. Quantifying angiographic image sequences can provide vital information, but it is not possible to perform this in a controlled manner in vivo. Computational fluid dynamics (CFD) is a valuable tool capable of providing high fidelity quantitative data by replicating the blood flow physics within the cerebrovasculature. In this work, we use simulated angiograms (SA) to quantify the hemodynamic interaction with a clinically utilized contrast agent. SA enables extraction of time density curves (TDC) within the desired region of interest to analyze hemodynamic parameters such as time to peak (TTP) and mean transit time (MTT) within the aneurysm. We present on the quantification of several hemodynamic parameters of interest for multiple, clinically-relevant scenarios such as variable contrast injection duration and bolus volumes for 7 patient-specific CA geometries. Results indicate that utilizing these analyses provides valuable hemodynamic information relating vascular and aneurysm morphology, contrast flow conditions and injection variability. The injected contrast circulates for multiple cardiac cycles within the aneurysmal region, especially for larger aneurysms and tortuous vasculature. The SA approach enables determination of angiographic parameters for each scenario. Together, these have the potential to overcome the existing barriers in quantifying angiographic procedures in vitro or in vivo, and can provide clinically valuable hemodynamic insights for CA treatment.

Indexed as

Angiographic AnalysisAngiographic Parametric Imaging (API)Cerebral AneurysmComputational Fluid Dynamics (CFD)HemodynamicsSimulated AngiogramsTime Density Curve

Identifiers

PMID37425071
PMCPMC10327470
OpenAlexW4363650219

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked