Evidence map›Paper›PMID 37424902›Full record

ArticleFrontiers in cardiovascular medicine2023

Rapid cardiac ischemia detection with an epicardial graphene probe.

Grzegorz Suwalski, Marek Galanty, Beata Degórska, Jacek Sterna, Jan Frymus, Mikhal Baranski, Piotr Trębacz, Daniel Janczak, Sandra Lepak-Kuc, Małgorzata Jakubowska

Open access · goldAbstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 82% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Grzegorz SuwalskiDepartment of Cardiac Surgery, Military Institute of Medicine, Warsaw, Poland.
Marek GalantyDepartment of Small Animal Diseases and Clinic, Faculty of Veterinary Medicine, Warsaw University of Life Sciences, Warsaw, Poland.
Beata DegórskaDepartment of Small Animal Diseases and Clinic, Faculty of Veterinary Medicine, Warsaw University of Life Sciences, Warsaw, Poland.
Jacek SternaDepartment of Small Animal Diseases and Clinic, Faculty of Veterinary Medicine, Warsaw University of Life Sciences, Warsaw, Poland.
Jan FrymusDepartment of Small Animal Diseases and Clinic, Faculty of Veterinary Medicine, Warsaw University of Life Sciences, Warsaw, Poland.
Mikhal BaranskiDepartment of Small Animal Diseases and Clinic, Faculty of Veterinary Medicine, Warsaw University of Life Sciences, Warsaw, Poland.
Piotr TrębaczDepartment of Small Animal Diseases and Clinic, Faculty of Veterinary Medicine, Warsaw University of Life Sciences, Warsaw, Poland.
Daniel JanczakFaculty of Mechatronics, Warsaw University of Technology, Warsaw, Poland.
Sandra Lepak-KucFaculty of Mechatronics, Warsaw University of Technology, Warsaw, Poland.
Małgorzata JakubowskaFaculty of Mechatronics, Warsaw University of Technology, Warsaw, Poland.
Warsaw University of Life Sciences · PLWarsaw University of Technology · PLWojskowy Instytut Medycyny Lotniczej · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: In this study, a new probe was designed to enable electrocardiography of a rotated heart during cardiac surgery when skin electrodes became non-functional. This probe adhered non-invasively to the epicardium and collected the ECG signal independently from the position of the heart. The study compared the accuracy of cardiac ischemia detection between classic skin and epicardial electrodes in an animal model. Methods: Using six pigs, an open chest model was devised with cardiac ischemia induction by coronary artery ligation in two non-physiologic heart positions. Both the accuracy and the time of detection of electrocardiographic symptoms of acute cardiac ischemia were compared between skin and epicardial methods of signal collection. Results: Heart rotation to expose either the anterior or the posterior wall resulted in a distortion or loss of the ECG signal collected by skin electrodes after coronary artery ligation, standard skin ECG monitoring did not reveal any ischemia symptoms. Attachment of an epicardial probe on the anterior and posterior walls helped in the recovery of the normal ECG wave. After ligation of the coronary artery, the epicardial probes recorded cardiac ischemia within 40 s. Discussion: This study highlighted the effectiveness of ECG monitoring with epicardial probes in a rotated heart. It can be concluded that epicardial probes can detect the presence of acute ischemia of a rotated heart when skin ECG monitoring becomes ineffective.

Indexed as

cardiac ischemiacardiac surgerycoronary artery bypass graftingepicardial electrocardiographymyocardial infarction

Identifiers

PMID37424902
PMCPMC10323424
OpenAlexW4381686070

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.