Telemetric electroencephalography recording in anesthetized mice-A novel system using minimally-invasive needle electrodes with a wireless OpenBCI™ Cyton Biosensing Board.

Mohammad T Mansouri, Meah T Ahmed, Tuan Z Cassim, Matthias Kreuzer, Morgan C Graves, Thomas Fenzl, Paul S García

Open access · goldAbstract read
In one paragraph

Article in MethodsX, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
4.5field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Mohammad T MansouriDepartment of Anesthesiology, Vagelos College of Physicians and Surgeons, Columbia University, New York, NY 10032, USA.
Meah T AhmedDepartment of Anesthesiology, Vagelos College of Physicians and Surgeons, Columbia University, New York, NY 10032, USA.
Tuan Z CassimDepartment of Anesthesiology, Vagelos College of Physicians and Surgeons, Columbia University, New York, NY 10032, USA.
Matthias KreuzerDepartment of Anaesthesiology & Intensive Care, School of Medicine, Technical University of Munich, Munich, Germany.
Morgan C GravesDepartment of Anesthesiology, Vagelos College of Physicians and Surgeons, Columbia University, New York, NY 10032, USA.
Thomas FenzlDepartment of Anaesthesiology & Intensive Care, School of Medicine, Technical University of Munich, Munich, Germany.
Paul S GarcíaDepartment of Anesthesiology, Vagelos College of Physicians and Surgeons, Columbia University, New York, NY 10032, USA.
Columbia University · USTechnical University of Munich · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Telemetric electroencephalography (EEG) recording, using subdermal needle electrodes, is a minimally-invasive method to investigate mammalian neurophysiology during anesthesia. These inexpensive systems may streamline experiments examining global brain phenomena during surgical anesthesia or disease. We utilized the OpenBCI™ Cyton board with subdermal needle electrodes to extract EEG features in six C57BL/6J mice undergoing isoflurane anesthesia. Burst suppression ratio (BSR) and spectral features were compared for a verification of our method. Following an increase from 1.5% to 2.0% isoflurane, the BSR increased (Wilcoxon-signed-rank statistic; p = 0.0313). Furthermore, although the absolute EEG spectral power decreased, the relative spectral power remained comparable (Wilcoxon-Mann-Whitney U-Statistic; 95% CI exclusive AUC=0.5; p < 0.05). Compared to tethered systems, this method confers several improvements for anesthesia specific protocols: 1-Avoiding electrode implant surgical procedures, 2-Anatomical non-specificity for needle electrode placement to monitor global cortical activity representative of anesthetic state, 3-Facility to repeat recordings in the same animal, 4-User-friendly for non-experts, 5-Rapid set-up time, and 6-Lower costs.•Minimally-invasive telemetric EEG recording systems ergonomically improve tethered systems for anesthesia protocols.•Using this method, we verified that higher isoflurane concentrations resulted in an increased EEG burst suppression ratio and decreased EEG absolute spectral power, with no change in frequency distribution.

Indexed as

AnesthesiaBurst suppressionElectroencephalographyIsofluraneSubdermal needle electrodeTelemetric Electroencephalography Recording in Anesthetized Mice Using Minimally-invasive Needle Electrodes with A Wireless OpenBCI TM Cyton Biosensing BoardTelemetry

Identifiers

PMID37424756
PMCPMC10326441
OpenAlexW4365815228

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.