Evidence map›Paper›PMID 37424017›Full record

ReviewBiomedical engineering online2023

Home-based upper limb stroke rehabilitation mechatronics: challenges and opportunities.

Shane Forbrigger, Vincent G DePaul, T Claire Davies, Evelyn Morin, Keyvan Hashtrudi-Zaad

Abstract readReview
In one paragraph

Review in Biomedical engineering online, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Shane ForbriggerDepartment of Electrical and Computer Engineering, Queen's University, Kingston, Canada.
Vincent G DePaulSchool of Rehabilitation Therapy, Queen's University, Kingston, Canada.
T Claire DaviesDepartment of Mechanical and Materials Engineering, Queen's University, Kingston, Canada.
Evelyn MorinDepartment of Electrical and Computer Engineering, Queen's University, Kingston, Canada.
Keyvan Hashtrudi-ZaadDepartment of Electrical and Computer Engineering, Queen's University, Kingston, Canada. khz@queensu.ca.

Funding

Faculty of Engineering and Applied Science, Queen's University, Canada 12063Natural Sciences and Engineering Research Council of Canada RGPIN-05609
6 · The paper itself

Abstract

Interest in home-based stroke rehabilitation mechatronics, which includes both robots and sensor mechanisms, has increased over the past 12 years. The COVID-19 pandemic has exacerbated the existing lack of access to rehabilitation for stroke survivors post-discharge. Home-based stroke rehabilitation devices could improve access to rehabilitation for stroke survivors, but the home environment presents unique challenges compared to clinics. The present study undertakes a scoping review of designs for at-home upper limb stroke rehabilitation mechatronic devices to identify important design principles and areas for improvement. Online databases were used to identify papers published 2010-2021 describing novel rehabilitation device designs, from which 59 publications were selected describing 38 unique designs. The devices were categorized and listed according to their target anatomy, possible therapy tasks, structure, and features. Twenty-two devices targeted proximal (shoulder and elbow) anatomy, 13 targeted distal (wrist and hand) anatomy, and three targeted the whole arm and hand. Devices with a greater number of actuators in the design were more expensive, with a small number of devices using a mix of actuated and unactuated degrees of freedom to target more complex anatomy while reducing the cost. Twenty-six of the device designs did not specify their target users' function or impairment, nor did they specify a target therapy activity, task, or exercise. Twenty-three of the devices were capable of reaching tasks, 6 of which included grasping capabilities. Compliant structures were the most common approach of including safety features in the design. Only three devices were designed to detect compensation, or undesirable posture, during therapy activities. Six of the 38 device designs mention consulting stakeholders during the design process, only two of which consulted patients specifically. Without stakeholder involvement, these designs risk being disconnected from user needs and rehabilitation best practices. Devices that combine actuated and unactuated degrees of freedom allow a greater variety and complexity of tasks while not significantly increasing their cost. Future home-based upper limb stroke rehabilitation mechatronic designs should provide information on patient posture during task execution, design with specific patient capabilities and needs in mind, and clearly link the features of the design to users' needs.

Indexed as

COVID-19RoboticsStrokeStroke RehabilitationAftercareHumansPandemicsPatient DischargeUpper ExtremityDesign methodsPhysical patient–robot interactionRehabilitation robotics

Identifiers

PMID37424017
PMCPMC10329803

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.