Evidence map›Paper›PMID 37421338›Full record

ReviewEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology2023

Cardiac pacing and lead devices management: 25 years of research at EP Europace journal.

Pascal Defaye, Mauro Biffi, Mikhael El-Chami, Serge Boveda, Michael Glikson, Jonathan Piccini, Marco Vitolo

Abstract readReview
In one paragraph

Review in Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 47 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
47citing papers in PubMed, 4 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

47 citing papers in PubMed, 4 syntheses or guidelines pooled it.

  1. Pooled it
  2. Guideline
  3. Pooled it
  4. Systematic review and meta-analysis on the impact on outcomes of device algorithms for minimizing right ventricular pacing.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2024
    Pooled it
  5. Atrioventricular synchrony maintained by a dual-chamber leadless pacemaker in real-world conditions.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
    Trial
  6. Trial
  7. Battery longevity of a helix-fixation dual-chamber leadless pacemaker: results from the AVEIR DR i2i Study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Trial
  8. Surgical skill simulation training to proficiency reduces procedural errors among novice cardiac device implanters: a randomized study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2024
    Trial
  9. Article
  10. Article
  11. Leadless pacemaker implantation in the region of Bachmann's bundle: initial results.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
    Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Review
  17. Cardiac implantable electronic device upgrades and downgrades: a Clinical Consensus Statement of the European Heart Rhythm Association (EHRA) of the ESC, the Asia Pacific Heart Rhythm Association (APHRS), Canadian Heart Rhythm Society (CHRS), Heart Rhythm Society (HRS), and the Latin American Heart Rhythm Society (LAHRS).Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Article
  18. Article
  19. Article
  20. Micra leadless pacemaker revisions: incidence, characteristics, and outcomes from a multicentre French cohort.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Pascal DefayeCardiology Department, University Hospital and Grenoble Alpes University, CS 10217, Grenoble Cedex 9, Grenoble 38043, France.ORCID 0000-0002-7183-4278
Mauro BiffiCardiology Unit, Cardiac Thoracic and Vascular Department, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy.ORCID 0000-0003-4590-8584
Mikhael El-ChamiDepartment of Medicine, Division of Cardiology, Emory University School of Medicine, Atlanta, Georgia, USA.ORCID 0000-0003-4978-7177
Serge BovedaClinique Pasteur, Heart Rhythm Department, Toulouse, France.ORCID 0000-0002-1280-7042
Michael GliksonCardiology Department, Jesselson Integrated Heart Center Shaare Zedek Medical Center and Hebrew University Faculty of Medicine, Jerusalem, Israel.ORCID 0000-0001-5706-0395
Jonathan PicciniDuke University, Duke Clinical Research Institute, Durham, NC, USA.ORCID 0000-0003-0772-2404
Marco VitoloCardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico Di Modena, Modena, Italy.ORCID 0000-0002-5196-6249

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsCardiac pacing represents a key element in the field of electrophysiology and the treatment of conduction diseases. Since the first issue published in 1999, EP Europace has significantly contributed to the development and dissemination of the research in this area.

methodsIn the last 25 years, there has been a continuous improvement of technologies and a great expansion of clinical indications making the field of cardiac pacing a fertile ground for research still today. Pacemaker technology has rapidly evolved, from the first external devices with limited longevity, passing through conventional transvenous pacemakers to leadless devices. Constant innovations in pacemaker size, longevity, pacing mode, algorithms, and remote monitoring highlight that the fascinating and exciting journey of cardiac pacing is not over yet.

conclusionThe aim of the present review is to provide the current 'state of the art' on cardiac pacing highlighting the most important contributions from the Journal in the field.

Indexed as

Cardiac Pacing, ArtificialPacemaker, ArtificialArrhythmias, CardiacCardiac Conduction System DiseaseEquipment DesignHumansCardiac pacingCIEDLeadless pacingPacemakerState of the art

Identifiers

PMID37421338
PMCPMC10450798

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.