Observational studyJournal of the American Heart Association2023
Poor Concordance of One-Third Anterior-Posterior Chest Diameter Measurements With Absolute Age-Specific Chest Compression Depth Targets in Pediatric Cardiac Arrest Patients.
Observational study in Journal of the American Heart Association, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Chest compression metrics during infant basic life support using 15:2 and 10:2 compression-ventilation ratios: a randomized crossover simulation study.Resuscitation plus · 2026Article
- Comparison of paediatric basic life support guidelines endorsed by member councils of Resuscitation Council of Asia.Resuscitation plus · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background Current pediatric cardiac arrest guidelines recommend depressing the chest by one-third anterior-posterior diameter (APD), which is presumed to equate to absolute age-specific chest compression depth targets (4 cm for infants and 5 cm for children). However, no clinical studies during pediatric cardiac arrest have validated this presumption. We aimed to study the concordance of measured one-third APD with absolute age-specific chest compression depth targets in a cohort of pediatric patients with cardiac arrest. Methods and Results This was a retrospective observational study from a multicenter, pediatric resuscitation quality collaborative (pediRES-Q [Pediatric Resuscitation Quality Collaborative]) from October 2015 to March 2022. In-hospital patients with cardiac arrest ≤12 years old with APD measurements recorded were included for analysis. One hundred eighty-two patients (118 infants >28 days old to <1 year old, and 64 children 1 to 12 years old) were analyzed. The mean one-third APD of infants was 3.2 cm (SD, 0.7 cm), which was significantly smaller than the 4 cm target depth (
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.