Evidence map›Paper›PMID 37421100›Full record

ArticleMicromachines2023

Design of a Compact Analog Complex Correlator for Millimeter-Wave Radiation Temperature Measurement System.

Wangdong He, Anyong Hu, Chen Dong, Xi Chen, Jianhao Gong, Jungang Miao

Abstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Wangdong HeSchool of Electronics and Information Engineering, Beihang University, Beijing 100191, China.
Anyong HuSchool of Electronics and Information Engineering, Beihang University, Beijing 100191, China.
Chen DongSchool of Electronics and Information Engineering, Beihang University, Beijing 100191, China.
Xi ChenSchool of Electronics and Information Engineering, Beihang University, Beijing 100191, China.ORCID 0000-0003-0204-9185
Jianhao GongSchool of Electronics and Information Engineering, Beihang University, Beijing 100191, China.
Jungang MiaoSchool of Electronics and Information Engineering, Beihang University, Beijing 100191, China.

Funding

National Key Research and Development Program of China 2022YFF0605901
6 · The paper itself

Abstract

Human body temperature is a fundamental physiological sign that reflects the state of physical health. It is important to achieve high-accuracy detection for non-contact human body temperature measurement. In this article, a Ka band (32 to 36 GHz) analog complex correlator using the integrated six-port chip is proposed, and a millimeter-wave thermometer system based on the designed correlator is completed for human body temperature measurement. The designed correlator utilizes the six-port technique to achieve large bandwidth and high sensitivity, and miniaturization of the correlator is achieved through an integrated six-port chip. By performing the single-frequency test and the broadband noise measurement on the correlator, we can determine that the dynamic range of input power of the correlator is -70 dBm to -35 dBm, and the correlation efficiency and equivalent bandwidth are 92.5% and 3.42 GHz, respectively. Moreover, the output of the correlator varies linearly with the input noise power, which reveals that the designed correlator is suitable for the field of human body temperature measurement. Then, a handheld thermometer system, with a size of 140 mm × 47 mm × 20 mm, is proposed using the designed correlator, and the measurement results show that the temperature sensitivity of the thermometer is less than 0.2 K.

Indexed as

analog complex correlatorKa bandmicrowave radiometernoise measurementsix-portthermometer

Identifiers

PMID37421100
PMCPMC10145961

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.