ArticleMicromachines2023
Multiphase Actuation of AC Electrothermal Micropump.
Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- CMOS Electrokinetic Systems and Fabrication Approaches for On-CMOS 3D Electrodes.Electrophoresis · 2026Review
- Thermal Effects in Microfluidic Electrokinetic Flows: From Limitation to Design Opportunity.Micromachines · 2026Review
- Editorial for the Special Issue on AC Electrokinetics in Microfluidic Devices, Volume II.Micromachines · 2024Article
- Microfluidic Mixing: A Physics-Oriented Review.Micromachines · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Electrothermal micropumps apply an AC electric field to a conductive fluid within the range of 10 kHz-1 MHz to generate fluid flow. In this frequency range, coulombic forces dominate fluid interactions over opposing dielectric forces, resulting in high flow rates (~50-100 μm/s). To date, the electrothermal effect-using asymmetrical electrodes-has been tested only with single-phase and 2-phase actuation, while dielectrophoretic micropumps have shown improved flow rates with 3- and 4-phase actuation. Simulating muti-phase signals in COMSOL Multiphysics requires additional modules and a more involved implementation to accurately represent the electrothermal effect in a micropump. Here, we report detailed simulations of the electrothermal effect under multi-phase conditions, including single-phase, 2-phase, 3-phase and 4-phase actuation patterns. These computational models indicate that 2-phase actuation leads to the highest flow rate, with 3-phase resulting in a 5% reduced flow rate and 4-phase resulting in an 11% reduced flow rate compared to 2-phase. With these modifications to the simulation, various actuation patterns can later be tested in COMSOL for a range of electrokinetic techniques.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.