Evidence map›Paper›PMID 37420991›Full record

ArticleMicromachines2023

Multiphase Actuation of AC Electrothermal Micropump.

Stirling Cenaiko, Thomas Lijnse, Colin Dalton

Abstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Stirling CenaikoBiomedical Engineering Department, University of Calgary, Calgary, AB T2N 1N4, Canada.
Thomas LijnseBiomedical Engineering Department, University of Calgary, Calgary, AB T2N 1N4, Canada.ORCID 0000-0003-4049-5215
Colin DaltonBiomedical Engineering Department, University of Calgary, Calgary, AB T2N 1N4, Canada.ORCID 0000-0001-7855-2727

Funding

Natural Sciences and Engineering Research Council RGPIN-2020-04542
6 · The paper itself

Abstract

Electrothermal micropumps apply an AC electric field to a conductive fluid within the range of 10 kHz-1 MHz to generate fluid flow. In this frequency range, coulombic forces dominate fluid interactions over opposing dielectric forces, resulting in high flow rates (~50-100 μm/s). To date, the electrothermal effect-using asymmetrical electrodes-has been tested only with single-phase and 2-phase actuation, while dielectrophoretic micropumps have shown improved flow rates with 3- and 4-phase actuation. Simulating muti-phase signals in COMSOL Multiphysics requires additional modules and a more involved implementation to accurately represent the electrothermal effect in a micropump. Here, we report detailed simulations of the electrothermal effect under multi-phase conditions, including single-phase, 2-phase, 3-phase and 4-phase actuation patterns. These computational models indicate that 2-phase actuation leads to the highest flow rate, with 3-phase resulting in a 5% reduced flow rate and 4-phase resulting in an 11% reduced flow rate compared to 2-phase. With these modifications to the simulation, various actuation patterns can later be tested in COMSOL for a range of electrokinetic techniques.

Indexed as

electrokineticelectrothermalmicropumpmultiphasesimulation

Identifiers

PMID37420991
PMCPMC10145383

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.