Evidence map›Paper›PMID 37420975›Full record

ArticleMicromachines2023

Compensation Method for the Nonlinear Characteristics with Starting Error of a Piezoelectric Actuator in Open-Loop Controls Based on the DSPI Model.

Dong An, Ji Li, Songhua Li, Meng Shao, Weinan Wang, Chuan Wang, Yixiao Yang

Abstract read
In one paragraph

Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Dong AnSchool of Mechanical Engineering, Shenyang Jianzhu University, Shenyang 110168, China.
Ji LiSchool of Mechanical Engineering, Shenyang Jianzhu University, Shenyang 110168, China.
Songhua LiSchool of Mechanical Engineering, Shenyang Jianzhu University, Shenyang 110168, China.ORCID 0000-0002-6487-6779
Meng ShaoSchool of Mechanical Engineering, Shenyang Jianzhu University, Shenyang 110168, China.
Weinan WangSchool of Mechanical Engineering, Shenyang Jianzhu University, Shenyang 110168, China.
Chuan WangSchool of Mechanical Engineering, Shenyang Jianzhu University, Shenyang 110168, China.
Yixiao YangSchool of Microelectronics, Fudan University, Shanghai 200433, China.

Funding

Basic scientific research Project of Education Department of Liaoning Province LJKMZ20220915The National Science Foundation of China No. 51975130
6 · The paper itself

Abstract

Nanopositioning stages with piezoelectric actuators have been widely used in fields such as precision mechanical engineering, but the nonlinear start-up accuracy problem under open-loop control has still not been solved, and more errors will accumulate, especially under open-loop control. This paper first analyzes the causes of the starting errors from both the physical properties of materials and voltages: the starting errors are affected by the material properties of piezoelectric ceramics, and the magnitude of the voltage determines the magnitude of the starting errors. Then, this paper adopts an image-only model of the data separated by a Prandtl-Ishlinskii model (DSPI) based on the classical Prandtl-Ishlinskii model (CPI), which can improve the positioning accuracy of the nanopositioning platform after separating the data based on the start-up error characteristics. This model can improve the positioning accuracy of the nanopositioning platform while solving the problem of nonlinear start-up errors under open-loop control. Finally, the DSPI inverse model is used for the feedforward compensation control of the platform, and the experimental results show that the DSPI model can solve the nonlinear start-up error problem existing under open-loop control. The DSPI model not only has higher modeling accuracy than the CPI model but also has better performance in terms of compensation results. The DSPI model improves the localization accuracy by 99.427% compared to the CPI model. When compared with another improved model, the localization accuracy is improved by 92.763%.

Indexed as

DSPI modelmaterial physical characteristicspiezoelectric actuatorsstart-up accuracy

Identifiers

PMID37420975
PMCPMC10145252

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.