Evidence map›Paper›PMID 37420842›Full record

ArticleSensors (Basel, Switzerland)2023

Joint Calibration of a Multimodal Sensor System for Autonomous Vehicles.

Jon Muhovič, Janez Perš

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Jon MuhovičFaculty of Electrical Engineering, University of Ljubljana, Tržaška Cesta 25, SI-1000 Ljubljana, Slovenia.ORCID 0000-0002-4082-2506
Janez PeršFaculty of Electrical Engineering, University of Ljubljana, Tržaška Cesta 25, SI-1000 Ljubljana, Slovenia.ORCID 0000-0002-6039-6110

Funding

Slovenian Research Agency J2-2506Slovenian Research Agency P2-0095
6 · The paper itself

Abstract

Multimodal sensor systems require precise calibration if they are to be used in the field. Due to the difficulty of obtaining the corresponding features from different modalities, the calibration of such systems is an open problem. We present a systematic approach for calibrating a set of cameras with different modalities (RGB, thermal, polarization, and dual-spectrum near infrared) with regard to a LiDAR sensor using a planar calibration target. Firstly, a method for calibrating a single camera with regard to the LiDAR sensor is proposed. The method is usable with any modality, as long as the calibration pattern is detected. A methodology for establishing a parallax-aware pixel mapping between different camera modalities is then presented. Such a mapping can then be used to transfer annotations, features, and results between highly differing camera modalities to facilitate feature extraction and deep detection and segmentation methods.

Indexed as

Autonomous VehiclesAwarenessCalibrationRefraction, Ocularannotationautonomous vehiclecalibrationmultimodal systemUSV

Identifiers

PMID37420842
PMCPMC10301019

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.