Evidence map›Paper›PMID 37420786›Full record

ArticleSensors (Basel, Switzerland)2023

Automated Signal Quality Assessment of Single-Lead ECG Recordings for Early Detection of Silent Atrial Fibrillation.

Markus Lueken, Michael Gramlich, Steffen Leonhardt, Nikolaus Marx, Matthias D Zink

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
3.5field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 16 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. [Digital competence in rhythmology : Training and education].Herzschrittmachertherapie & Elektrophysiologie · 2024
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Markus LuekenMedical Information Technology (MedIT), Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, 52074 Aachen, Germany.ORCID 0000-0002-2487-0962
Michael GramlichDepartment of Internal Medicine I-Cardiology, University Hospital RWTH, 52074 Aachen, Germany.ORCID 0000-0001-5233-6778
Steffen LeonhardtMedical Information Technology (MedIT), Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, 52074 Aachen, Germany.ORCID 0000-0002-6898-6887
Nikolaus MarxDepartment of Internal Medicine I-Cardiology, University Hospital RWTH, 52074 Aachen, Germany.
Matthias D ZinkDepartment of Internal Medicine I-Cardiology, University Hospital RWTH, 52074 Aachen, Germany.
RWTH Aachen University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Atrial fibrillation (AF) is an arrhythmic cardiac disorder with a high and increasing prevalence in aging societies, which is associated with a risk for stroke and heart failure. However, early detection of onset AF can become cumbersome since it often manifests in an asymptomatic and paroxysmal nature, also known as silent AF. Large-scale screenings can help identifying silent AF and allow for early treatment to prevent more severe implications. In this work, we present a machine learning-based algorithm for assessing signal quality of hand-held diagnostic ECG devices to prevent misclassification due to insufficient signal quality. A large-scale community pharmacy-based screening study was conducted on 7295 older subjects to investigate the performance of a single-lead ECG device to detect silent AF. Classification (normal sinus rhythm or AF) of the ECG recordings was initially performed automatically by an internal on-chip algorithm. The signal quality of each recording was assessed by clinical experts and used as a reference for the training process. Signal processing stages were explicitly adapted to the individual electrode characteristics of the ECG device since its recordings differ from conventional ECG tracings. With respect to the clinical expert ratings, the artificial intelligence-based signal quality assessment (AISQA) index yielded strong correlation of 0.75 during validation and high correlation of 0.60 during testing. Our results suggest that large-scale screenings of older subjects would greatly benefit from an automated signal quality assessment to repeat measurements if applicable, suggest additional human overread and reduce automated misclassifications.

Indexed as

Atrial FibrillationStrokeAlgorithmsArtificial IntelligenceElectrocardiographyHumansatrial fibrillationECG signal quality assessmentsingle-lead ECG screening

Identifiers

PMID37420786
PMCPMC10302320
OpenAlexW4380988348

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.