Evidence map›Paper›PMID 37420731›Full record

ArticleSensors (Basel, Switzerland)2023

Estimation of Spatio-Temporal Parameters of Gait and Posture of Visually Impaired People Using Wearable Sensors.

Karla Miriam Reyes Leiva, Miguel Ángel Cuba Gato, José Javier Serrano Olmedo

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 2 countries.

Karla Miriam Reyes LeivaEngineering Faculty, Universidad Tecnológica Centroamericana UNITEC, San Pedro Sula 21101, Honduras.
Miguel Ángel Cuba GatoCenter for Biomedical Technology (CTB), Universidad Politécnica de Madrid, 28040 Madrid, Spain.ORCID 0000-0001-6920-0965
José Javier Serrano OlmedoCenter for Biomedical Technology (CTB), Universidad Politécnica de Madrid, 28040 Madrid, Spain.ORCID 0000-0002-8544-8933
Universidad Politécnica de Madrid · ESCentral American Technological University · HN

Funding

Ministerio de ciencia, Innovación y universidades PGC2018-097531-B-I0
6 · The paper itself

Abstract

In rehabilitating orientation and mobility (O&M) for visually impaired people (VIP), the measurement of spatio-temporal gait and postural parameters is of specific interest for rehabilitators to assess performance and improvements in independent mobility. In the current practice of rehabilitation worldwide, this assessment is carried out in people with estimates made visually. The objective of this research was to propose a simple architecture based on the use of wearable inertial sensors for quantitative estimation of distance traveled, step detection, gait velocity, step length and postural stability. These parameters were calculated using absolute orientation angles. Two different sensing architectures were tested for gait according to a selected biomechanical model. The validation tests included five different walking tasks. There were nine visually impaired volunteers in real-time acquisitions, where the volunteers walked indoor and outdoor distances at different gait velocities in their residences. The ground truth gait characteristics of the volunteers in five walking tasks and an assessment of the natural posture during the walking tasks are also presented in this article. One of the proposed methods was selected for presenting the lowest absolute error of the calculated parameters in all of the traveling experimentations: 45 walking tasks between 7 and 45 m representing a total of 1039 m walked and 2068 steps; the step length measurement was 4.6 ± 6.7 cm with a mean of 56 cm (11.59 Std) and 1.5 ± 1.6 relative error in step count, which compromised the distance traveled and gait velocity measurements, presenting an absolute error of 1.78 ± 1.80 m and 7.1 ± 7.2 cm/s, respectively. The results suggest that the proposed method and its architecture could be used as a tool for assistive technology designed for O&M training to assess gait parameters and/or navigation, and that a sensor placed in the dorsal area is sufficient to detect noticeable postural changes that compromise heading, inclinations and balancing in walking tasks.

Indexed as

GaitWearable Electronic DevicesHumansPostureVolunteersWalkinginertial sensorsO&Mpostural assessmentrehabilitation

Identifiers

PMID37420731
PMCPMC10303222
OpenAlexW4380684471

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.