Evidence map›Paper›PMID 37420621›Full record

ArticleSensors (Basel, Switzerland)2023

Utility and Usability of Two Forms of Supplemental Vibrotactile Kinesthetic Feedback for Enhancing Movement Accuracy and Efficiency in Goal-Directed Reaching.

Ramsey K Rayes, Rachel N Mazorow, Leigh A Mrotek, Robert A Scheidt

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 3 citations in OpenAlex.

  1. Trial
  2. Article
  3. 3-Dimensional Vibrotactile Feedback Training Promotes Positive User Experience and Improvement in Reach-to-Grasp Kinematics.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2024
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Ramsey K RayesJoint Department of Biomedical Engineering, Marquette University and the Medical College of Wisconsin, Milwaukee, WI 53233, USA.ORCID 0000-0002-0058-1971
Rachel N MazorowJoint Department of Biomedical Engineering, Marquette University and the Medical College of Wisconsin, Milwaukee, WI 53233, USA.ORCID 0009-0000-7071-9449
Leigh A MrotekJoint Department of Biomedical Engineering, Marquette University and the Medical College of Wisconsin, Milwaukee, WI 53233, USA.
Robert A ScheidtJoint Department of Biomedical Engineering, Marquette University and the Medical College of Wisconsin, Milwaukee, WI 53233, USA.ORCID 0000-0002-2024-5051
Marquette University · US

Funding

Medical Student Training in Aging and Injury ResearchT35AG029793 · NIA · MEDICAL COLLEGE OF WISCONSIN · PI MEURER, LINDA N. · 2007 to 2021
$1.0M
Augmenting kinesthetic feedback to improve hemiparetic arm control after strokeR15HD093086 · NICHD · MARQUETTE UNIVERSITY · PI SCHEIDT, ROBERT A. · 2017 to 2021
$897k
NIA NIH HHS T35AG029793NICHD NIH HHS R15 HD093086
6 · The paper itself

Abstract

Recent advances in wearable sensors and computing have made possible the development of novel sensory augmentation technologies that promise to enhance human motor performance and quality of life in a wide range of applications. We compared the objective utility and subjective user experience for two biologically inspired ways to encode movement-related information into supplemental feedback for the real-time control of goal-directed reaching in healthy, neurologically intact adults. One encoding scheme mimicked visual feedback encoding by converting real-time hand position in a Cartesian frame of reference into supplemental kinesthetic feedback provided by a vibrotactile display attached to the non-moving arm and hand. The other approach mimicked proprioceptive encoding by providing real-time arm joint angle information via the vibrotactile display. We found that both encoding schemes had objective utility in that after a brief training period, both forms of supplemental feedback promoted improved reach accuracy in the absence of concurrent visual feedback over performance levels achieved using proprioception alone. Cartesian encoding promoted greater reductions in target capture errors in the absence of visual feedback (Cartesian: 59% improvement; Joint Angle: 21% improvement). Accuracy gains promoted by both encoding schemes came at a cost in terms of temporal efficiency; target capture times were considerably longer (1.5 s longer) when reaching with supplemental kinesthetic feedback than without. Furthermore, neither encoding scheme yielded movements that were particularly smooth, although movements made with joint angle encoding were smoother than movements with Cartesian encoding. Participant responses on user experience surveys indicate that both encoding schemes were motivating and that both yielded passable user satisfaction scores. However, only Cartesian endpoint encoding was found to have passable usability; participants felt more competent using Cartesian encoding than joint angle encoding. These results are expected to inform future efforts to develop wearable technology to enhance the accuracy and efficiency of goal-directed actions using continuous supplemental kinesthetic feedback.

Indexed as

GoalsQuality of LifeAdultFeedbackHumansKinesthesisMovementProprioceptioncartesian endpoint encodinghand kinematicsjoint angle encodingmovement decompositionsensory augmentationuser experience

Identifiers

PMID37420621
PMCPMC10302602
OpenAlexW4380079547

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.