ArticleSensors (Basel, Switzerland)2023

Shoulder Range of Motion Measurement Using Inertial Measurement Unit-Validation with a Robot Arm.

Martyna Białecka, Kacper Gruszczyński, Paweł Cisowski, Jakub Kaszyński, Cezary Baka, Przemysław Lubiatowski

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Martyna BiałeckaRehasport Clinic, Gorecka 30, 60-201 Poznan, Poland.ORCID 0000-0002-0409-3123
Kacper GruszczyńskiRSQ Technologies Company, 27 Grudnia 3, 61-737 Poznan, Poland.
Paweł CisowskiRehasport Clinic, Gorecka 30, 60-201 Poznan, Poland.
Jakub KaszyńskiRehasport Clinic, Gorecka 30, 60-201 Poznan, Poland.ORCID 0000-0001-5031-1227
Cezary BakaRehasport Clinic, Gorecka 30, 60-201 Poznan, Poland.ORCID 0000-0003-3539-6693
Przemysław LubiatowskiRehasport Clinic, Gorecka 30, 60-201 Poznan, Poland.

Funding

European Regional Development Fund under the Operational Program Smart Growth POIR.01.01.01-00-0837 / 17Ministry of Science and Higher Education 0612/SBAD/3606
6 · The paper itself

Abstract

The invention of inertial measurement units allowed the construction of sensors suitable for human motion tracking that are more affordable than expensive optical motion capture systems, but there are a few factors influencing their accuracy, such as the calibration methods and the fusion algorithms used to translate sensor readings into angles. The main purpose of this study was to test the accuracy of a single RSQ Motion sensor in comparison to a highly precise industrial robot. The secondary objectives were to test how the type of sensor calibration affects its accuracy and whether the time and magnitude of the tested angle have an impact on the sensor's accuracy. We performed sensor tests for nine repetitions of nine static angles made by the robot arm in eleven series. The chosen robot movements mimicked shoulder movements in a range of motion test (flexion, abduction, and rotation). The RSQ Motion sensor appeared to be very accurate, with a root-mean-square error below 0.15°. Furthermore, we found a moderate-to-strong correlation between the sensor error and the magnitude of the measured angle but only for the sensor calibrated with the gyroscope and accelerometer readings. Although the high accuracy of the RSQ Motion sensors was demonstrated in this paper, they require further study on human subjects and comparisons to the other devices known as the gold standards in orthopedics.

Indexed as

RoboticsShoulderBiomechanical PhenomenaHumansMotionMovementRange of Motion, ArticularRotationinertial measurement unitrange of motionsensor accuracyshouldervalidation

Identifiers

PMID37420531
PMCPMC10304346

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.