Evidence map›Paper›PMID 37418161›Full record

ArticleJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2024

Development of modified laser Doppler flowmetry device for real-time monitoring of esophageal mucosal blood flow: a preclinical assessment with an animal model.

Shun-Ichi Kawarai, Shintaro Katahira, Midori Miyatake, Kota Itagaki, Noriko Tsuruoka, Yoichi Haga, Yoshikatsu Saiki

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Shun-Ichi KawaraiDivision of Cardiovascular Surgery, Hachinohe City Hospital, 3-1-1 Tamukai, Hachinohe, Aomori, 031-8555, Japan.
Shintaro KatahiraDivision of Cardiovascular Surgery, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-Ku, Sendai, 980-8574, Japan. shinkatahira@med.tohoku.ac.jp.
Midori MiyatakeDivision of Cardiovascular Surgery, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-Ku, Sendai, 980-8574, Japan.
Kota ItagakiDivision of Cardiovascular Surgery, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-Ku, Sendai, 980-8574, Japan.
Noriko TsuruokaTohoku University Graduate School of Engineering, 6-6-12 Aoba, Aramaki, Aoba-Ku, Sendai, 980-8579, Japan.
Yoichi HagaTohoku University Graduate School of Biomedical Engineering, 6-6-12 Aoba, Aramaki, Aoba-Ku, Sendai, 980-8579, Japan.
Yoshikatsu SaikiDivision of Cardiovascular Surgery, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-Ku, Sendai, 980-8574, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to modify a laser Doppler flowmeter designed and assembled at our institute. After measuring sensitivity evaluation in ex vivo experiments, we confirmed the efficacy of this new device for monitoring real-time esophageal mucosal blood flow changes after thoracic stent graft implantation by simulating various clinical situations in an animal model. Thoracic stent graft implantation was performed in a swine model (n = 8). Esophageal mucosal blood flow decreased significantly from baseline (34.1 ± 18.8 ml/min/100 g vs. 16.7 ± 6.6 ml/min/100 g, P < 0.05) in the lower esophagus (Th6-Th8) where the stent graft covered the aorta. In the hemorrhagic shock model (shock index ≥ 1.0), esophageal mucosal blood flow showed a remarkable change from baseline in the upper esophagus (Th1-Th3), where the stent graft did not cover the aorta (20.8 ± 9.8 ml/min/100 g vs. 12.9 ± 8.6 ml/min/100 g, P < 0.01); however, it returned to the baseline value within a 30-min period. Mucosal blood flow remained stable in the esophagus, where the stent graft did not cover the aorta. After elevating the mean blood pressure to > 70 mmHg with continuous intravenous noradrenaline infusion, esophageal mucosal blood flow increased significantly in both regions; however, the reaction was different between the two regions. Our newly developed laser Doppler flowmeter could measure real-time esophageal mucosal blood flow changes in various clinical situations during thoracic stent graft implantation in a swine model. Hence, this device can be applied in many medical fields by downsizing it.

Indexed as

Disease Models, AnimalLaser-Doppler FlowmetryAnimalsEsophageal MucosaEsophagusMaleRegional Blood FlowShock, HemorrhagicStentsSwineEsophageal mucosal blood flowHemorrhagic shockLaser Doppler flowmeterNoradrenalineThoracic endovascular aortic repair

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390