Evidence map›Paper›PMID 37417563›Full record

ArticleInvestigative and clinical urology2023

Retroperitoneal robot-assisted laparoscopic nephroureterectomy using the da Vinci Xi and SP systems: Initial experiences in cadaveric models.

Shuichi Morizane, Hubert Stein, Takayuki Komiya, Hiroyuki Kaneta, Atsushi Takenaka

Abstract read
In one paragraph

Article in Investigative and clinical urology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Shuichi MorizaneDivision of Urology, Department of Surgery, Faculty of Medicine, Tottori University, Yonago, Japan. morizane@tottori-u.ac.jp.ORCID 0000-0003-0344-5892
Hubert SteinDepartment of Surgical Applications Engineering, Intuitive Surgical Inc., Sunnyvale, CA, USA.ORCID 0000-0003-0193-4369
Takayuki KomiyaDepartment of Surgical Applications Engineering, Intuitive Surgical Inc., Sunnyvale, CA, USA.ORCID 0009-0006-8703-2807
Hiroyuki KanetaDepartment of Surgical Applications Engineering, Intuitive Surgical Inc., Sunnyvale, CA, USA.ORCID 0009-0006-7012-4588
Atsushi TakenakaDivision of Urology, Department of Surgery, Faculty of Medicine, Tottori University, Yonago, Japan.ORCID 0000-0002-7756-4926

Funding

Intuitive Surgical Inc.
6 · The paper itself

Abstract

purposeTo investigate the feasibility and optimal port placements of robot-assisted laparoscopic nephroureterectomy (RANU) via the retroperitoneal approach in the lateral decubitus and supine positions using the da Vinci Xi (DVXi) and da Vinci SP (DVSP) systems. MATERIALS AND

methodsWe performed lateral decubitus extraperitoneal RANU on the right side and supine extraperitoneal RANU on the left side using the DVXi and DVSP systems without repositioning in two fresh cadavers. In addition, paracaval and pelvic lymphadenectomies were performed simultaneously during both surgical procedures. The operative time of each procedure was calculated, and the technical details associated with these procedures were evaluated.

resultsLateral decubitus and supine extraperitoneal RANU using the DVXi and DVSP systems were achieved without repositioning. The surgeon console time ranged from 89 to 178 minutes, and no major technical complications were observed. However, carbon dioxide insufflation into the abdominal cavity was observed owing to a peritoneal breach during the creation of the surgical workspace, particularly in the supine position. Compared with the DVXi system, the DVSP system was more suitable for RANU using the retroperitoneal approach, except for renal handling.

conclusionsThe DVXi and DVSP systems are feasible for performing lateral decubitus and supine extraperitoneal RANU without patient repositioning. The lateral decubitus position may be better than the supine position, and the DVSP system is more suitable for retroperitoneal RANU than the DVXi system. Nevertheless, further studies should be performed in clinical settings to validate our results.

Indexed as

LaparoscopyRoboticsRobotic Surgical ProceduresCadaverHumansNephroureterectomyRetroperitoneal SpaceCadaverNephroureterectomyRetroperitoneal spaceRoboticsSupine position

Identifiers

PMID37417563
PMCPMC10330408

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.