Evidence map›Paper›PMID 37415424›Full record

ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2025

Benchtop evaluation of a double stent retriever thrombectomy technique for acute ischemic stroke treatment.

Jeremy Hofmeister, Gianmarco Bernava, Andrea Rosi, Philippe Reymond, Olivier Brina, Michel Muster, Karl-Olof Lovblad, Paolo Machi

Abstract read
In one paragraph

Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Potential of Guidewire-Clot Interaction Forces for Clot Detection in Robotic Mechanical Thrombectomy.The international journal of medical robotics + computer assisted surgery : MRCAS · 2025
    Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jeremy HofmeisterDepartment of Diagnostics, Diagnostic and Interventional Neuroradiology Unit, Geneva University Hospitals, Geneva, Switzerland.ORCID 0000-0002-0071-8499
Gianmarco BernavaDepartment of Diagnostics, Diagnostic and Interventional Neuroradiology Unit, Geneva University Hospitals, Geneva, Switzerland.ORCID 0000-0003-2037-5558
Andrea RosiDepartment of Diagnostics, Diagnostic and Interventional Neuroradiology Unit, Geneva University Hospitals, Geneva, Switzerland.
Philippe ReymondDepartment of Diagnostics, Diagnostic and Interventional Neuroradiology Unit, Geneva University Hospitals, Geneva, Switzerland.
Olivier BrinaDepartment of Diagnostics, Diagnostic and Interventional Neuroradiology Unit, Geneva University Hospitals, Geneva, Switzerland.
Michel MusterDepartment of Diagnostics, Diagnostic and Interventional Neuroradiology Unit, Geneva University Hospitals, Geneva, Switzerland.
Karl-Olof LovbladDepartment of Diagnostics, Diagnostic and Interventional Neuroradiology Unit, Geneva University Hospitals, Geneva, Switzerland.
Paolo MachiDepartment of Diagnostics, Diagnostic and Interventional Neuroradiology Unit, Geneva University Hospitals, Geneva, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purposeA mechanical thrombectomy technique using a double stent retriever approach has been reported for the treatment of patients with acute ischemic stroke. The purpose of this study was to perform a benchtop evaluation of the mechanism of action and efficacy of a double-stent retriever approach compared to a single-stent retriever approach.Materials and methodsIn vitro, mechanical thrombectomy procedures were performed in a vascular phantom reproducing an M1-M2 occlusion with two different clot analog consistencies (soft and hard). We compared the double stent retriever approach to the single stent retriever approach and recorded the recanalization rate, distal embolization, and retrieval forces of each mechanical thrombectomy procedure.ResultsThe double stent retriever approach achieved a higher recanalization rate and lower embolic complications compared to the single stent retriever approach. This seems to stem from two facts: the greater probability of targeting the correct artery with two stents in the case of bifurcation occlusion, and an improved clot capture mechanism using the double stent retriever approach. However, the double stent retriever was associated with an increased initial retrieval force.ConclusionsIn vitro evaluation of the mechanism of action of the double stent retriever provided explanations that appear to support the high efficacy of such an approach in patient cohorts and could help operators when selecting the optimal mechanical thrombectomy strategy in cases of arterial occlusions difficult to treat with a single stent retriever.

Indexed as

Ischemic StrokeStentsThrombectomyHumansPhantoms, ImagingTreatment Outcomeefficacyin vitromechanical thrombectomystent retrieverStroke

Identifiers

PMID37415424
PMCPMC12475382

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.