ArticleMedical physics2023
Quantitative performance of photon-counting CT at low dose: Virtual monochromatic imaging and iodine quantification.
Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
24 citing papers in PubMed, 33 citations in OpenAlex.
- Evaluation of iodine detection and quantification limits in photon-counting CT-a phantom study.European radiology experimental · 2026Article
- Photon-counting CT in head and neck radiology: bridging detector physics and clinical applications.European radiology · 2026Review
- Understanding Photon-Counting CT: Physics, Detector Technology, and Image Reconstructions.Sensors (Basel, Switzerland) · 2026Review
- Photon-counting detector computed tomography in thoracic oncology: revolutionizing tumor imaging through precision and detail.Diagnostic and interventional radiology (Ankara, Turkey) · 2026Review
- CT of Soft Tissue Infections: Current and Future Perspectives from Diagnosis to Treatment.Journal of clinical medicine · 2026Review
- Analysis of colorectal liver metastases in photon-counting detector CT - optimizing imaging through spectral reconstruction.Cancer imaging : the official publication of the International Cancer Imaging Society · 2026Article
- Proton therapy range uncertainty reduction using vendor-agnostic tissue characterization on a virtual photon-counting CT head scan.Medical physics · 2026Article
- Phantom-derived method for improving accurate material decomposition in photon-counting detector CT.European radiology experimental · 2026Article
- Comparison of iodine quantification accuracy on prototype deep silicon photon-counting and energy-integrating detector CT.Abdominal radiology (New York) · 2026Article
- Quantitative Enhancement of Spectral Imaging in Photon-Counting CT via Dynamic Energy Thresholding.Proceedings of SPIE--the International Society for Optical Engineering · 2026Article
- Performance of virtual unenhanced images on a prototype silicon photon counting detector CT: preliminary clinical results.BMC biomedical engineering · 2026Article
- Photon-counting detector CT in oncology: a new era of cancer imaging.Insights into imaging · 2026Review
- Assessment of Image Quality Performance of a Photon-Counting Computed Tomography Scanner Approved for Whole-Body Clinical Applications.Sensors (Basel, Switzerland) · 2025Article
- Three-dimensional noise characteristics of clinical photon counting detector CT.Medical physics · 2025Article
- Assessing the stability of photon-counting CT: insights from a 2-year longitudinal study.European radiology · 2025Article
- Influence of phantom design on evaluation metrics in photon counting spectral head CT: a simulation study.Journal of medical imaging (Bellingham, Wash.) · 2025Article
- Clinical photon-counting CT increases CT number precision and reduces patient size dependence compared to single- and dual-energy CT.The British journal of radiology · 2025Article
- Contrast-enhanced photon-counting detector CT for discriminating local recurrence from postoperative changes after resection of pancreatic ductal adenocarcinoma.European radiology experimental · 2025Article
- Performance of iodine quantification through high-pitch dual-source photon-counting CT: a phantom study.Japanese journal of radiology · 2025Article
- Voxelwise characterization of noise for a clinical photon-counting CT scanner with a model-based iterative reconstruction algorithm.European radiology experimental · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 2 countries.
Funding
Abstract
backgroundQuantitative imaging techniques, such as virtual monochromatic imaging (VMI) and iodine quantification (IQ), have proven valuable diagnostic methods in several specific clinical tasks such as tumor and tissue differentiation. Recently, a new generation of computed tomography (CT) scanners equipped with photon-counting detectors (PCD) has reached clinical status. PURPOSE: This work aimed to investigate the performance of a new photon-counting CT (PC-CT) in low-dose quantitative imaging tasks, comparing it to an earlier generation CT scanner with an energy-integrating detector dual-energy CT (DE-CT). The accuracy and precision of the quantification across size, dose, material types (including low and high iodine concentrations), displacement from iso-center, and solvent (tissue background) composition were explored.
methodsQuantitative analysis was performed on two clinical scanners, Siemens SOMATOM Force and NAEOTOM Alpha using a multi-energy phantom with plastic inserts mimicking different iodine concentrations and tissue types. The tube configurations in the dual-energy scanner were 80/150Sn kVp and 100/150Sn kVp, while for PC-CT both tube voltages were set to either 120 or 140 kVp with photon-counting energy thresholds set at 20/65 or 20/70 keV. The statistical significance of patient-related parameters in quantitative measurements was examined using ANOVA and pairwise comparison with the posthoc Tukey honest significance test. Scanner bias was assessed in both quantitative tasks for relevant patient-specific parameters.
resultsThe accuracy of IQ and VMI in the PC-CT was comparable between standard and low radiation doses (p < 0.01). The patient size and tissue type significantly affect the accuracy of both quantitative imaging tasks in both scanners. The PC-CT scanner outperforms the DE-CT scanner in the IQ task in all cases. Iodine quantification bias in the PC-CT (-0.9 ± 0.15 mg/mL) at low doses in our study was comparable to that of DE-CT (range -2.6 to 1.5 mg/mL, published elsewhere) at a 1.7× higher dose, but the dose reduction severely biased DE-CT (4.72 ± 0.22 mg/mL). The accuracy in Hounsfield units (HU) estimation was comparable for 70 and 100 keV virtual imaging between scanners, but PC-CT was significantly underestimating virtual 40 keV HU values of dense materials in the phantom representing the extremely obese population.
conclusionsThe statistical analysis of our measurements reveals better IQ at lower radiation doses using new PC-CT. Although VMI performance was mostly comparable between the scanners, the DE-CT scanner quantitatively outperformed PC-CT when estimating HU values in the specific case of very large phantoms and dense materials, benefiting from increased X-ray tube potentials.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.