ArticleSurgical endoscopy2023
Not deep enough: Modeling the effect of shallow placement of the DaVinci Xi "bariatric" long trocar on the muscular abdominal wall.
Article in Surgical endoscopy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThe DaVinci Xi Robotic Surgical System (Xi) long cannula (Intuitive Surgical Company, Sunnyvale, CA) provides five additional centimeters of distal length compared to the standard Xi trocar. The extra length allows the cannula to traverse prohibitively thick body wall tissue. Our aims are to quantitatively model the consequences of not preserving the rotational centerpoint of motion (RCM) at the muscular abdominal wall. This is an essential tenet in robotic surgery; it is violated with shallow placement of the long trocar. This leads to unchecked, unnoticed blunt widening of port sites by the robotic arm, increasing hernia risk.
methodsWe begin with an exploration of the schematic of the Xi robotic arm as patented by Intuitive (U.S. Patent #5931832). We trigonometrically model the lateral displacement of the abdominal wall at the trocar site with respect to vertical trocar shallowness, instrument tip depth, and instrument tip lateral motion from neutral midline.
resultsThe rigid parallelogram movement structure of the Xi preserves the RCM at the thick black marker printed on every Xi cannula. By limitation of design, both long and standard trocars must have this marker at the exact same distance from their proximal end. The value ranges of our model parameters (presuming a reasonable maximum orientation angle of 45° from midline) are: trocar shallowness [1 cm, 7 cm]; instrument tip depth [0 cm, 20 cm]; instrument tip lateral movement [0.0 cm, 14.1 cm]. Abdominal wall displacement increased proportionally as each instrument tip parameter reached its maximum deviation from the orthogonal midline as described in the plot figure. Maximal wall displacement at maximal shallowness was approximately 7.0 cm.
conclusionRobotic surgery revolutionizes modern operation, particularly within bariatrics. However, the current Xi arm design disallows a true long trocar to be used safely without compromising the RCM, thereby risking hernia development.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.