Evidence map›Paper›PMID 37414919›Full record

ArticlePediatric research2023

Incubator-based active noise control device: comparison to ear covers and noise reduction zone quantification.

George M Hutchinson, Preston S Wilson, Scott Sommerfeldt, Kaashif Ahmad

Open access · hybridAbstract read
In one paragraph

Article in Pediatric research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
2.3field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 4 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 4 institutions in 1 country.

George M HutchinsonInvictus Medical, Inc., San Antonio, TX, USA. ghutchinson@invictusmed.com.ORCID http://orcid.org/0000-0002-9085-7790
Preston S WilsonMechanical Engineering, University of Texas at Austin, Austin, TX, USA.
Scott SommerfeldtDepartment of Physics and Astronomy, Brigham Young University, Provo, UT, USA.
Kaashif AhmadPediatrix Neonatology of Houston, Houston, TX, USA.
Brigham Young University · USDNAtrix (United States) · USInvictus Medical (United States) · USThe University of Texas at Austin · US

Funding

Incubator-based active noise control system validation in realistic NICU environmentR43DC018464 · NIDCD · INVICTUS MEDICAL, INC. · PI HUTCHINSON, GEORGE · 2019 to 2019
$222k
NIDCD NIH HHS R43 DC018464
6 · The paper itself

Abstract

backgroundNoise exposure in the neonatal intensive care unit (NICU) is consistently higher than current recommendations. This may adversely affect neonatal sleep, weight gain, and overall health. We sought to evaluate the effect of a novel active noise control (ANC) system.

methodsAn ANC device's noise reduction performance was compared to that of adhesively affixed foam ear covers in response to alarm and voice sounds in a simulated NICU environment. The zone of noise reduction of the ANC device was quantified with the same set of alarm and voice sounds.

resultsThe ANC device provided greater noise reduction than the ear covers in seven of the eight sound sequences tested in which a noise reduction greater than the just noticeable difference was achieved. For noise in the 500 Hz octave band, the ANC device exhibited consistent noise reduction throughout expected patient positions. It provided better performance for noise below 1000 Hz than above 1000 Hz.

conclusionsThe ANC device provided generally superior noise reduction to the ear covers and provided a zone of noise reduction throughout the range where an infant would be placed within an incubator. Implications for patient sleep and weight gain are discussed. IMPACT: Active noise control device can effectively reduce noise inside an infant incubator due to bedside device alarms. This is the first analysis of an incubator-based active noise control device and comparison to adhesively affixed silicone ear covers. A non-contact noise reduction device may be an appropriate means of reducing noise exposure of the hospitalized preterm infant.

Indexed as

Infant, PrematureNoiseHumansIncubatorsInfantInfant, NewbornIntensive Care Units, NeonatalSoundWeight Gain

Identifiers

PMID37414919
PMCPMC10624623
OpenAlexW4383313779

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.