Evidence map›Paper›PMID 37409417›Full record

ArticleActa orthopaedica2023

Minimum 20-year follow-up of a press-fit acetabular cup in cementless total hip replacement in young patients.

Andre Lunz, Moritz Von Falkenhayn, Sebastian Jaeger, Tobias Reiner, Christian Merle, Marcus R Streit, Tobias Renkawitz, Moritz M Innmann

Open access · goldAbstract read
In one paragraph

Article in Acta orthopaedica, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 2 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Andre LunzDepartment of Orthopaedics, Heidelberg University Hospital, Heidelberg. andre.lunz@med.uni-heidelberg.de.
Moritz Von FalkenhaynDepartment of Orthopaedics, Heidelberg University Hospital, Heidelberg.
Sebastian JaegerDepartment of Orthopaedics, Heidelberg University Hospital, Heidelberg.
Tobias ReinerDepartment of Orthopaedics, Heidelberg University Hospital, Heidelberg.
Christian MerleDiakonie Klinikum Stuttgart.
Marcus R StreitARCUS Sportklinik, Pforzheim, Germany.
Tobias RenkawitzDepartment of Orthopaedics, Heidelberg University Hospital, Heidelberg.
Moritz M InnmannDepartment of Orthopaedics, Heidelberg University Hospital, Heidelberg.
Heidelberg University · DEARCUS Sports Clinic · DEDiakonie-Klinikum Stuttgart · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWe aimed to determine the minimum 20-year survival rates of a cementless press-fit cup in young patients. PATIENTS AND

methodsThis is a retrospective, single-center, multi-surgeon cohort study investigating the minimum 20-year clinical and radiological outcome of the first 121 consecutive total hip replacements (THRs) using a cementless, press-fit cup (Allofit, Zimmer, Warsaw, IN, USA) performed between 1999 and 2001. 28-mm metal-on-metal (MoM) and ceramic-on-conventionally not highly crosslinked polyethylene (CoP) bearings were used in 71% and 28%, respectively. Median patient age at surgery was 52 (range 21-60) years. Kaplan-Meier survival analysis was conducted for different endpoints.

resultsThe 22-year survival rate for the endpoint aseptic cup or inlay revision was 94% (95% confidence interval [CI] 87-96) and 99% (CI 94-100) for aseptic cup loosening. 20 patients (21 THRs; 17%) had died and 5 (5 THRs; 4%) were lost to follow-up. No THR showed evidence of radiographic cup loosening. Osteolysis was observed in 40% of THRs with MoM and 77% with CoP bearings. 88% of THRs with CoP bearings showed significant polyethylene wear.

conclusionThe investigated cementless press-fit cup, which is still in clinical use today, showed excellent long-term survival rates in patients under the age of 60 years at surgery. However, osteolysis due to polyethylene and metal wear was frequently observed and is a matter of concern in the third decade after surgery.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisOsteolysisAdultCohort StudiesFollow-Up StudiesHumansMetalsMiddle AgedPolyethyleneProsthesis DesignProsthesis FailureReoperationRetrospective StudiesYoung AdultMetalsPolyethylene

Identifiers

PMID37409417
PMCPMC10326741
OpenAlexW4383302949

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.