Evaluation of a planar diode matrix for SRS patient-specific QA in comparison with GAFchromic films.

Erminia Infusino, Anna Ianiro, Stefano Luppino, Sandro Nocentini, Cristina Pugliatti, Antonella Soriani

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Erminia InfusinoDepartment of Medical Physics, IRCCS Regina Elena National Cancer Institute - Rome, Italy.
Anna IaniroDepartment of Medical Physics, IRCCS Regina Elena National Cancer Institute - Rome, Italy.ORCID https://orcid.org/0000-0001-6870-5507
Stefano LuppinoDepartment of Medical Physics, IRCCS Regina Elena National Cancer Institute - Rome, Italy.
Sandro NocentiniDepartment of Medical Physics, IRCCS Regina Elena National Cancer Institute - Rome, Italy.
Cristina PugliattiDepartment of Medical Physics, Michele e Pietro Ferrero Hospital, Verduno, Italy.
Antonella SorianiDepartment of Medical Physics, IRCCS Regina Elena National Cancer Institute - Rome, Italy.ORCID https://orcid.org/0000-0002-2795-5603

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWe validate the routine use of a two-dimensional (2D) diode matrix for patient specific pre-treatment verification for Cyberknife (CK) stereotactic radiosurgery and to compare it with film dosimetry. MATERIALS AND

methodA total of 46 patients were selected according to the most frequent diseases treated at our institution with the CK system, that is, brain metastases, meningiomas, spine metastases, and prostate tumors. All cases were evaluated with GAFChromic EBT-3 films and SRS MapCHECK for Fixed cone, IRIS, and MLC collimators of the CK.

resultsThe highest mean passing rate was observed for the SRS MapCHECK system compared to films. In order to assess if the two techniques provide statistically different results, a Wilcoxon Signed-Rank non-parametric test was performed (p < 0.05) and we found gamma values significantly lower for EBT-3 films with respect to the SRS MapCHECK. We noticed a moderately significant association between the two techniques using Spearman's rank correlation coefficient (rs > 0.4). We also performed the Bland-Altman statistical method: less than 5% of the differences resulted outside the range (mean ± 1.96 × SD), so the two methods can be considered interchangeable within the combined inaccuracy.

conclusionsThe use of SRS MapCHECK for CK patient specific quality assurance (QA) is feasible for a variety of clinical districts and could be reliably used as a replacement for radiochromic films.

Indexed as

Brain NeoplasmsProstatic NeoplasmsRadiosurgeryFilm DosimetryHumansMaleRadiotherapy DosageCyberknifepre-treatment verificationquality assuranceradiosurgery

Identifiers

PMID37408167
PMCPMC10402681

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.