Evidence map›Paper›PMID 37407429›Full record

ArticleAnalytical chemistry2023

Electrospray Ion Mobility Spectrometer Based on Flexible Printed-Circuit Board Electrodes with Improved Resolving Power.

Marc-Aurèle Boillat, Julian M Rakus, Peter C Hauser

Abstract read
In one paragraph

Article in Analytical chemistry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Asynchronous Stepped Fourier Transform Ion Mobility Spectrometry.Journal of the American Society for Mass Spectrometry · 2026
    Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Marc-Aurèle BoillatDepartment of Chemistry, University of Basel, Klingelbergstrasse 80, 4056 Basel, Switzerland.
Julian M RakusDepartment of Chemistry, University of Basel, Klingelbergstrasse 80, 4056 Basel, Switzerland.
Peter C HauserDepartment of Chemistry, University of Basel, Klingelbergstrasse 80, 4056 Basel, Switzerland.ORCID 0000-0002-7506-5971

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

An easily built drift tube instrument with ring electrodes made of rolled-up flexible printed circuit boards is reported. Its resolving power was maximized by careful attention to the drift tube geometry and the response time of the detector amplifier and by employing a high separation field strength. The separation of singly charged aliphatic quaternary ammonium ions introduced by electrospray was performed, and the measured resolving power was between 86 and 97% of the theoretical limit for three different drift tube lengths investigated. For the longest drift length of 30 cm, a resolving power of up to 228 was obtained. Three benzalkonium chlorides were also separated with resolving powers of over 210. The tristate injection scheme can also be used, with only a small loss of the separation performance compared to the two-state injection.

Identifiers

PMID37407429
PMCPMC10357405

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.