Evidence map›Paper›PMID 37405897›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2023

Acoustoelectric Time-Reversal for Ultrasound Phase-Aberration Correction.

Chet Preston, Alexander M Alvarez, Margaret Allard, Andres Barragan, Russell S Witte

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Chet Preston
Alexander M Alvarez
Margaret Allard
Andres Barragan
Russell S Witte

Funding

4D Transcranial Acoustoelectric Imaging for High Resolution Functional Mapping of Neuronal CurrentsU01EB029834 · NIBIB · UNIVERSITY OF ARIZONA · PI WITTE, RUSSELL S · 2020 to 2024
$3.4M
Graduate Training in Biomedical Imaging SpectrocopyT32EB000809 · NIBIB · UNIVERSITY OF ARIZONA · PI GMITRO, ARTHUR F. · 2003 to 2018
$3.3M
Computational and Mathematical Modeling of Biomedical SystemsT32GM132008 · NIGMS · UNIVERSITY OF ARIZONA · PI Ryan Gutenkunst, JOANNA MASEL · 2019 to 2026
$2.3M
High School Student NeuroResearch Program (HSNRP)R25NS076437 · NINDS · UNIVERSITY OF ARIZONA · PI Frank Porreca, MARLYS Hearst WITTE · 2011 to 2026
$1.3M
High resolution electrical brain mapping by real-time and portable 4D Acoustoelectric ImagingR24MH109060 · NIMH · UNIVERSITY OF ARIZONA · PI WITTE, RUSSELL S · 2015 to 2017
$1.2M
4D Transcranial Acoustoelectric Imaging for High Resolution Functional Mapping of Neuronal CurrentsU01EB028662 · NIBIB · UNIVERSITY OF ARIZONA · PI WITTE, RUSSELL S · 2019 to 2019
$428k
NIBIB NIH HHS T32 EB000809NIBIB NIH HHS U01 EB028662NIBIB NIH HHS U01 EB029834NIGMS NIH HHS T32 GM132008NIMH NIH HHS R24 MH109060NINDS NIH HHS R25 NS076437
6 · The paper itself

Abstract

Acoustoelectric imaging (AEI) is a technique that combines ultrasound (US) with radio frequency recording to detect and map local current source densities. This study demonstrates a new method called acoustoelectric time reversal (AETR), which uses AEI of a small current source to correct for phase aberrations through a skull or other US-aberrating layers with applications to brain imaging and therapy. Simulations conducted at three different US frequencies (0.5, 1.5, and 2.5 MHz) were performed through media layered with different sound speeds and geometries to induce aberrations of the US beam. Time delays of the acoustoelectric (AE) signal from a monopole within the medium were calculated for each element to enable corrections using AETR. Uncorrected aberrated beam profiles were compared with those after applying AETR corrections, which demonstrated a strong recovery (29%-100%) of lateral resolution and increases in focal pressure up to 283%. To further demonstrate the practical feasibility of AETR, we further conducted bench-top experiments using a 2.5 MHz linear US array to perform AETR through 3-D-printed aberrating objects. These experiments restored lost lateral restoration up to 100% for the different aberrators and increased focal pressure up to 230% after applying AETR corrections. Cumulatively, these results highlight AETR as a powerful tool for correcting focal aberrations in the presence of a local current source with applications to AEI, US imaging, neuromodulation, and therapy.

Identifiers

PMID37405897
PMCPMC10493188

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.