Evidence map›Paper›PMID 37405016›Full record

ArticleCardiovascular diagnosis and therapy2023

Commissural and coronary alignment of the Venus-A valve after transcatheter aortic valve replacement: a retrospective cross-sectional study.

Siyu Xi, Haishan Zhang, Yuan Gao, Xin Chen, Wenfei Tan, Liang Guo, Yingxian Sun

Open access · diamondAbstract read
In one paragraph

Article in Cardiovascular diagnosis and therapy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Siyu XiDepartment of Cardiology, The First Hospital of China Medical University, Shenyang, China.
Haishan ZhangDepartment of Cardiology, The First Hospital of China Medical University, Shenyang, China.
Yuan GaoDepartment of Cardiology, The First Hospital of China Medical University, Shenyang, China.
Xin ChenDepartment of Cardiovascular Ultrasound, The First Hospital of China Medical University, Shenyang, China.
Wenfei TanDepartment of Anesthesiology, The First Hospital of China Medical University, Shenyang, China.
Liang GuoDepartment of Cardiology, The First Hospital of China Medical University, Shenyang, China.
Yingxian SunDepartment of Cardiology, The First Hospital of China Medical University, Shenyang, China.
First Hospital of China Medical University · CNChina Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Previous studies have shown that neo-commissural orientation of transcatheter heart valve (THV) can influence coronary obstruction during transcatheter aortic valve replacement (TAVR), long-term durability of THV, and coronary artery access for reintervention after TAVR. Specific initial orientations of Evolut R/Pro and Acurate Neo aortic valves can improve commissural alignment. However, the method of achieving commissural alignment with the Venus-A valve remains unknown. Therefore, this study aimed to evaluate the extent of commissural and coronary alignment of the Venus-A self-expanding valve after TAVR using a standard system delivery technique. Methods: A retrospective cross-sectional study was performed. At the time of enrollment, patients who underwent pre- and post-procedural electrocardiographically-gated contrast-enhanced CT with a second-generation 64-row multidetector scanner were selected for the study. Commissural alignment was categorized as aligned (0-15° angle deviation), mild (15-30°), moderate (30-45°), or severe (45-60°) commissural misalignment (CMA). Coronary alignment was categorized as having no coronary overlap (CO) (>35°), moderate CO (20-35°), or severe CO (≤20°). The results were represented as proportions to assess the extent of commissural and coronary alignment. Results: Forty-five TAVR patients were ultimately included in the analysis. THVs were shown to be randomly implanted: 20.0% of THVs were aligned, 33.3% had mild CMA, 26.7% had moderate CMA, and 20.0% had severe CMA. The incidence of severe CO was 24.4% with the left main coronary artery, 28.9% with the right coronary artery, 6.7% with both coronary arteries, and 46.7% with one or both coronary arteries. Conclusions: The results showed that commissural or coronary alignment could not be achieved with the Venus-A valve using a standard system delivery technique. Therefore, specific methods to attain alignment with the Venus-A valve need to be identified.

Indexed as

Commissural alignmentcoronary alignmenttranscatheter aortic valve replacement (TAVR)Venus-A self-expanding valve

Identifiers

PMID37405016
PMCPMC10315423
OpenAlexW4381544130

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.