The possibility of automatic capillary blood testing in routine blood tests: an evaluation of the automatic mode of the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood testing.
Article in Cardiovascular diagnosis and therapy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- The blood routine test holds screening values for influenza A in 2023: a retrospective study.Translational pediatrics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Capillary blood is a common specimen type used for infant blood routine tests. Until now, this specimen type could only be tested with the manual mode in hematology analyzers. Manual sample mixing and loading increases the amount labor force and can be more easily affected by human factors. This study was designed to investigate the proficiency of the automatic mode of the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood testing. Methods: The complete blood count (CBC) results for capillary blood were compared between the automatic and manual modes. Special types of samples, including samples with high or low volume, thalassemia red cells, high fibrinogen, high hematocrit (HCT), or high triglyceride levels, were compared and evaluated. The intraclass correlation coefficient (ICC) was used to define the agreement between the 2 modes. The industry standard Analytical Quality Specifications for Routine Tests in Clinical Hematology (WS/T 406-2012), published by the National Health Commission of China, was used to evaluate the correlation between the results from the 2 modes. Results: There was good correlation between the automatic and manual modes for every type of sample, and the ICCs were all higher than 0.9. Except for high HCT or high triglyceride samples, there were no differences found between the 2 modes based on the WS/T 406-2012 standard. Conclusions: This new automatic mode utilized in the Mindray BC-7500 CRP Auto Hematology Analyzer for capillary blood yielded the same results as the manual mode except in the case of samples with high HCT or triglycerides. Capillary blood might be routinely tested automatically with hematology analyzers in the near future, which might reduce the labor required and improve standardization.