Evidence map›Paper›PMID 37403349›Full record

ArticleRadiation oncology journal2023

Proton therapy for reducing heart and cardiac substructure doses in Indian breast cancer patients.

Sapna Nangia, Nagarjuna Burela, M P Noufal, Kartikeswar Patro, Manoj Gulabrao Wakde, Dayanada S Sharma

Open access · diamondAbstract read
In one paragraph

Article in Radiation oncology journal, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Review
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Sapna NangiaDepartment of Radiation Oncology, Apollo Proton Cancer Centre, Chennai, Tamil Nadu, India.
Nagarjuna BurelaDepartment of Radiation Oncology, Apollo Proton Cancer Centre, Chennai, Tamil Nadu, India.
M P NoufalDepartment of Medical Physics, Apollo Proton Cancer Centre, Chennai, Tamil Nadu, India.
Kartikeswar PatroDepartment of Medical Physics, Apollo Proton Cancer Centre, Chennai, Tamil Nadu, India.
Manoj Gulabrao WakdeDepartment of Medical Physics, Apollo Proton Cancer Centre, Chennai, Tamil Nadu, India.
Dayanada S SharmaDepartment of Medical Physics, Apollo Proton Cancer Centre, Chennai, Tamil Nadu, India.
Apollo Proton Cancer Centre · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIndians have a higher incidence of cardiovascular diseases, often at a younger age, than other ethnic groups. This higher baseline risk requires consideration when assessing additional cardiac morbidity of breast cancer treatment. Superior cardiac sparing is a critical dosimetric advantage of proton therapy in breast cancer radiotherapy. We report here the heart and cardiac-substructure doses and early toxicities in breast cancer patients treated post-operatively with proton therapy in India's first proton therapy center. MATERIALS AND

methodsWe treated twenty breast cancer patients with intensity-modulated proton therapy (IMPT) from October 2019 to September 2022, eleven after breast conservation, nine following mastectomy, and appropriate systemic therapy, when indicated. The most prescribed dose was 40 GyE to the whole breast/chest wall and 48 GyE by simultaneous integrated boost to the tumor bed and 37.5 GyE to appropriate nodal volumes, delivered in 15 fractions.

resultsAdequate coverage was achieved for clinical target volume (breast/chest wall), i.e., CTV40, and regional nodes, with 99% of the targets receiving 95% of the prescribed dose (V95% > 99%). The mean heart dose was 0.78 GyE and 0.87 GyE for all and left breast cancer patients, respectively. The mean left anterior descending artery (LAD) dose, LAD D0.02cc, and left ventricle dose were 2.76, 6.46, and 0.2 GyE, respectively. Mean ipsilateral lung dose, V20Gy, V5Gy, and contralateral breast dose (Dmean) were 6.87 GyE, 14.6%, 36.4%, and 0.38 GyE, respectively.

conclusionThe dose to heart and cardiac substructures is lower with IMPT than published photon therapy data. Despite the limited access to proton therapy at present, given the higher cardiovascular risk and coronary artery disease prevalence in India, the cardiac sparing achieved using this technique merits consideration for wider adoption in breast cancer treatment.

Indexed as

Breast cancerHeartPencil beam scanningProton beam therapyProtonsToxicity

Identifiers

PMID37403349
PMCPMC10326511
OpenAlexW4378895571

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.