ArticleCureus2023
Use of Flow-Volume Loops on a Mechanically Ventilated Pediatric Patient as a Diagnostic Tool for Fixed Airway Obstruction.
Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The flow-volume loop (FV-loop) provides a graphical representation of the inspiratory and expiratory flow of both mechanically provided breaths and patient-triggered breaths during invasive mechanical ventilation. The FV-loop on the ventilator-delivered breath displays the active inspiratory flow reflective of lung compliance and the passive expiratory flow reflective of airway resistance. Our case report highlights the importance of the FV-loop in determining a fixed airway obstruction. A five-month-old male presented to the emergency department with worsening respiratory distress in the setting of rhino-enterovirus. He was admitted to the pediatric intensive care unit (PICU) and intubated for acute hypoxic respiratory failure. The findings on his ventilator FV-loop graphics denoted a fixed airway obstruction, as seen by the truncation of inspiratory and expiratory flow. The patient was subsequently found to have a left pulmonary artery (LPA) sling with a vascular ring and several complete tracheal rings. He was transferred to a referral institution for operative management, returned to our PICU, and discharged home after 47 days of hospital management. During mechanical ventilation, FV-loops can be effectively utilized to assist in the diagnosis of fixed intra- or extra-thoracic airway obstructions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.