Evidence map›Paper›PMID 37396690›Full record

ArticleAnaesthesia reports

Contamination of the central medical air supply with water leading to mass ventilator failure.

J J X Chia, M H Goh, M M Goh, C W S Teo, K H Tan, D W Sewa, H F Ng

Abstract readCase Reports
In one paragraph

Article in Anaesthesia reports. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

J J X ChiaDepartment of Anaesthesiology Singapore General Hospital Singapore.
M H GohDepartment of Anaesthesiology Singapore General Hospital Singapore.
M M GohDepartment of Nursing Singapore General Hospital Singapore.
C W S TeoDepartment of Respiratory Therapy Singapore General Hospital Singapore.
K H TanDepartment of Anaesthesiology Singapore General Hospital Singapore.
D W SewaDepartment of Respiratory and Critical Care Medicine Singapore General Hospital Singapore.
H F NgDepartment of Biomedical Engineering Singapore General Hospital Singapore.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Here, we present a case of mass ventilator failure due to contaminated medical air. Multiple ventilators failed routine tests, including almost all of the ventilators in our intensive care unit. A faulty air compressor had led to water contamination of our centre's supply of medical air. Water entered the pipeline supply of air and, hence the ventilators and anaesthetic machines. The disruption of the machines' proportional mixer valve resulted in unreliable delivery of fresh gas flow. This malfunction was discovered during routine pre-use checks, and backup ventilators were available to replace the faulty ventilators. A shortage of equipment was averted due to a serendipitous availability of ventilator stockpiles prepared for the COVID-19 pandemic. Ventilator shortages are commonly described in mass casualty and pandemic scenarios. While there are multiple strategies described in literature to augment and maximise equipment available for mechanical ventilation, stockpiling equipment remains an expensive but necessary component of disaster contingency planning.

Indexed as

anaesthesia machinecompressorcontaminationgas deliverymedical air

Identifiers

PMID37396690
PMCPMC10313312

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.