ArticleEJVES vascular forum2023
Automatic Detection of Visceral Arterial Aneurysms on Computed Tomography Angiography Using Artificial Intelligence Based Segmentation of the Vascular System.
Article in EJVES vascular forum, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Progress in fully automated abdominal CT interpretation-an update over the past decade.Abdominal radiology (New York) · 2026Review
- Validation of a Deep Learning U-Net Algorithm for Multistructure Segmentation of Infrarenal Abdominal Aortic Aneurysms including Lumen, Thrombus, and Calcifications.EJVES vascular forum · 2026Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Visceral arterial aneurysms (VAAs) are life threatening. Due to the paucity of symptoms and rarity of the disease, VAAs are underdiagnosed and underestimated. Artificial intelligence (AI) offers new insights into segmentation of the vascular system, and opportunities to better detect VAAs. This pilot study aimed to develop an AI based method to automatically detect VAAs from computed tomography angiography (CTA). Methods: A hybrid method combining a feature based expert system with a supervised deep learning algorithm (convolutional neural network) was used to enable fully automatic segmentation of the abdominal vascular tree. Centrelines were built and reference diameters of each visceral artery were calculated. An abnormal dilatation (VAAs) was defined as a substantial increase in diameter at the pixel of interest compared with the mean diameter of the reference portion. The automatic software provided 3D rendered images with a flag on the identified VAA areas. The performance of the method was tested in a dataset of 33 CTA scans and compared with the ground truth provided by two human experts. Results: Forty-three VAAs were identified by human experts (32 in the coeliac trunk branches, eight in the superior mesenteric artery, one in the left renal, and two in the right renal arteries). The automatic system accurately detected 40 of the 43 VAAs, with a sensitivity of 0.93 and a positive predictive value of 0.51. The mean number of flag areas per CTA was 3.5 ± 1.5 and they could be reviewed and checked by a human expert in less than 30 seconds per CTA. Conclusion: Although the specificity needs to be improved, this study demonstrates the potential of an AI based automatic method to develop new tools to improve screening and detection of VAAs by automatically attracting clinicians' attention to suspicious dilatations of the visceral arteries.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.