Evidence map›Paper›PMID 37396150›Full record

ArticleResults in chemistry2023

A sensitive UPLC-MS/MS method for the simultaneous assay and trace level genotoxic impurities quantification of SARS-CoV-2 inhibitor-Molnupiravir in its pure and formulation dosage forms using fractional factorial design.

Srinivas Nakka, Siva Krishna Muchakayala, Surendra Babu Manabolu Surya

Abstract read
In one paragraph

Article in Results in chemistry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Srinivas NakkaDepartment of Chemistry, School of Science, GITAM Deemed to be University, Hyderabad 502329, India.
Siva Krishna MuchakayalaDepartment of Chemistry, School of Science, GITAM Deemed to be University, Hyderabad 502329, India.
Surendra Babu Manabolu SuryaDepartment of Chemistry, School of Science, GITAM Deemed to be University, Hyderabad 502329, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Two potential genotoxic impurities were identified (PGTIs)-viz. 4-amino-1-((2R,3R,4S,5R)-3,4-dihydroxy-5-(hydroxymethyl)tetrahydrofuran-2-yl)pyrimidin-2(1H)-one (PGTI-1), and 1-(2R,3R,4S,5R)-3,4-dihydroxy-5-(hydroxymethyl)tetrahydrofuran-2-yl)pyrimidin-2,4(1H,3H)-one (PGTI-II) in the Molnupiravir (MOPR) synthetic routes. COVID-19 disease was treated with MOPR when mild to moderate symptoms occurred. Two (Q)-SAR methods were used to assess the genotoxicity, and projected results were positive and categorized into Class-3 for both PGTIs. A simple, accurate and highly sensitive ultra-performance liquid chromatography-mass spectrometry (UPLC-MS/MS) method was optimized for the simultaneous quantification of the assay, and these impurities in MOPR drug substance and formulation dosage form. The multiple reaction monitoring (MRM) technique was utilized for the quantification. Prior to the validation study, the UPLC-MS method conditions were optimised using fractional factorial design (FrFD). The optimized Critical Method Parameters (CMPs) include the percentage of Acetonitrile in MP B, Concentration of Formic acid in MP A, Cone Voltage, Capillary Voltage, Collision gas flow and Desolvation temperature were determined from the numerical optimization to be 12.50 %, 0.13 %, 13.6 V, 2.6 kV, 850 L/hr and 375 °C, respectively. The optimized chromatographic separation achieved on Waters Acquity HSS T3 C18 column (100 mm × 2.1 mm, 1.8 µm) in a gradient elution mode with 0.13% formic acid in water and acetonitrile as mobile phases, column temperature kept at 35 °C and flow rate at 0.5 mL/min. The method was successfully validated as per ICH guidelines, and demonstrated excellent linearity over the concentration range of 0.5-10 ppm for both PGTIs. The Pearson correlation coefficient of each impurity and MOPR was found to be higher than 0.999, and the recoveries were in between the range of 94.62 to 104.05% for both PGTIs and 99.10 to 100.25% for MOPR. It is also feasible to utilise this rapid method to quantify MOPR accurately in biological samples.

Indexed as

Fractional factorial designMolnupiravirPotential genotoxic impurities(Q)-SARUPLC-MS/MS

Identifiers

PMID37396150
PMCPMC10293121

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.