ArticleEFORT open reviews2023
Custom triflange acetabular components for large acetabular defect reconstruction in revision total hip arthroplasty: a systematic review and meta-analysis on 1218 patients.
Article in EFORT open reviews, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 1 synthesis or guideline pooled it.
- The outcomes of acetabular impaction bone grafting using allografts in uncemented cups for acetabular bone loss: a systematic review and meta-analysis.Musculoskeletal surgery · 2026Pooled it
- A pile foundation reconstruction prosthesis for severe acetabular bone defects : principle, design, and mechanical analysis.Bone & joint research · 2026Article
- Custom-made acetabular implants for severe acetabular bone defects: implant evolution, mid-term clinical and radiographic outcomes, and complications in 154 consecutive patients over 18 years.Arthroplasty (London, England) · 2026Article
- Article
- Assessment of Custom-Made Acetabular Implants for Complex Revision Total Hip Arthroplasty: A Concise Follow-up, at a Minimum of 5 Years.The Journal of bone and joint surgery. American volume · 2026Article
- Implementation of an Intraoperative Augmented Reality Environment for Custom-Made Partial Pelvis Replacements-A Proof of Concept and Initial Results.Journal of personalized medicine · 2026Article
- Graft Incorporation and Cup Migration in Acetabular Impaction Bone Grafting for Revision Hip Arthroplasty: A Systematic Review and Meta-Analysis of 1093 Hips.Arthroplasty today · 2026Article
- High retention rates of custom 3D printed titanium implants in complex pelvic reconstruction, a report on 106 consecutive cases over 10 years.Archives of orthopaedic and trauma surgery · 2025Article
- Multiple revision surgeries after total hip arthroplasty in a patient with osteopetrosis: a case report with 24 years of follow-up.BMC musculoskeletal disorders · 2025Article
- Finite Element Analysis of a 3D-Printed Acetabular Prosthesis for an Acetabular Defect According to the Paprosky Classification.Materials (Basel, Switzerland) · 2025Article
- CORR Insights®: What Are the Functional, Radiographic, and Survivorship Outcomes of a Modified Cup-cage Technique for Pelvic Discontinuity?Clinical orthopaedics and related research · 2024Article
- Joint preservation in revision arthroplasty and intercalary tumour implants using custom stem solutions.BMC musculoskeletal disorders · 2024Article
- Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: This is a systematic review and meta(regression) analysis to assess the performance of custom triflange acetabular components (CTAC) in total hip arthroplasty (THA) revision surgery. Implant-related complications, failure rate, functional outcomes and implant and surgical technique-related predictors for outcome were assessed. Methods: This systematic review was performed according to PRISMA guidelines and registered with PROSPERO (2020 CRD42020209700). PubMed, Embase, Web of Science, COCHRANE Library and Emcare were searched. Studies on Paprosky type 3A and 3B or AAOS type 3 and 4 acetabular defects with a minimum follow-up of 12 months and cohorts > 10 patients were included. Results: Thirty-three studies were eligible for inclusion (n = 1235 hips, 1218 patients). The methodological quality of the studies was moderate (AQUILA: 7.4/11 points). Considerable heterogeneity was observed in terms of complications, re-operations and implant failure reporting. The total incidence of implant-related complications was 24%. The incidence of re-operation for any reason was 15%, and the implant failure rate was 12% at a mean of 46.9 months and the post-operative Harris Hip Score improved by a mean of 40 points. Several predictors for outcome were found, such as implant generation, follow-up length and study start date. Conclusions: The use of CTAC in revision THA has satisfactory complication and implant failure rates. The CTAC technique improves post-operative clinical outcomes and the meta-regression analysis showed that there is a clear association between improvements in the CTAC performance and the evolvement of this technique over time.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.