FluoroPi Device With SmartProbes: A Frugal Point-of-Care System for Fluorescent Detection of Bacteria From a Pre-Clinical Model of Microbial Keratitis.

Syam Mohan P C Mohanan, Kay Russell, Sheelagh Duncan, Alex Kiang, Charles Lochenie, Emma Duffy, Stephnie Kennedy, N Venkatesh Prajna, Rachel L Williams, Kevin Dhaliwal and 2 more

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 3 institutions in 2 countries.

Syam Mohan P C MohananTranslational Healthcare Technologies Group, Centre for Inflammation Research, University of Edinburgh, Edinburgh, UK.
Kay RussellTranslational Healthcare Technologies Group, Centre for Inflammation Research, University of Edinburgh, Edinburgh, UK.
Sheelagh DuncanTranslational Healthcare Technologies Group, Centre for Inflammation Research, University of Edinburgh, Edinburgh, UK.
Alex KiangTranslational Healthcare Technologies Group, Centre for Inflammation Research, University of Edinburgh, Edinburgh, UK.
Charles LochenieTranslational Healthcare Technologies Group, Centre for Inflammation Research, University of Edinburgh, Edinburgh, UK.
Emma DuffyTranslational Healthcare Technologies Group, Centre for Inflammation Research, University of Edinburgh, Edinburgh, UK.
Stephnie KennedyDepartment of Eye and Vision Science, University of Liverpool, Liverpool, UK.
N Venkatesh PrajnaDepartment of Cornea and Refractive Surgery, Aravind Eye Hospital, Madurai, India.
Rachel L WilliamsDepartment of Eye and Vision Science, University of Liverpool, Liverpool, UK.
Kevin DhaliwalTranslational Healthcare Technologies Group, Centre for Inflammation Research, University of Edinburgh, Edinburgh, UK.
Gareth O S WilliamsTranslational Healthcare Technologies Group, Centre for Inflammation Research, University of Edinburgh, Edinburgh, UK.
Bethany MillsTranslational Healthcare Technologies Group, Centre for Inflammation Research, University of Edinburgh, Edinburgh, UK.
Centre for Inflammation Research · GBUniversity of Liverpool · GBAravind Eye Hospital · IN

Funding

Medical Research Council MR/R006334/1Medical Research Council MR/V026097/1Wellcome TrustWellcome Trust 206035/Z/17/Z
6 · The paper itself

Abstract

Purpose: Rapid and accurate diagnosis of microbial keratitis (MK) could greatly improve patient outcomes. Here, we present the development of a rapid, accessible multicolour fluorescence imaging device (FluoroPi) and evaluate its performance in combination with fluorescent optical reporters (SmartProbes) to distinguish bacterial Gram status. Furthermore, we show feasibility by imaging samples obtained by corneal scrape and minimally invasive corneal impression membrane (CIM) from ex vivo porcine corneal MK models. Methods: FluoroPi was built using a Raspberry Pi single-board computer and camera, light-emitting-diodes (LEDs), and filters for white-light and fluorescent imaging, with excitation and detection of bacterial optical SmartProbes: Gram-negative, NBD-PMX (exmax 488 nm); Gram positive, Merocy-Van (exmax 590 nm). We evaluated FluoroPi with bacteria (Pseudomonas aeruginosa and Staphylococcus aureus) isolated from ex vivo porcine corneal models of MK by scrape (needle) and CIM with the SmartProbes. Results: FluoroPi provides <1 µm resolution and was able to readily distinguish bacteria isolated from ex vivo models of MK from tissue debris when combined with SmartProbes, retrieved by both scrape and CIM. Single bacteria could be resolved within the field of view, with limits of detection demonstrated as 103 to 104 CFU/mL. Sample preparation prior to imaging was minimal (wash-free), and imaging and postprocessing with FluoroPi were straightforward, confirming ease of use. Conclusions: FluoroPi coupled with SmartProbes provides effective, low-cost bacterial imaging, delineating Gram-negative and Gram-positive bacteria directly sampled from a preclinical model of MK. Translational Relevance: This study provides a crucial stepping stone toward clinical translation of a rapid, minimally invasive diagnostic approach for MK.

Indexed as

Eye Infections, BacterialKeratitisAnimalsBacteriaCorneaPoint-of-Care SystemsSwine

Identifiers

PMID37395707
PMCPMC10324419
OpenAlexW4382918423

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.