ArticleZeitschrift fur medizinische Physik2025

Physical wedge as a tool for radiochromic film calibration.

Stevan Pecić, Miloš Vićić, Ivan Belča, Strahinja Stojadinović, Borko Nidžović, Ljubomir Kurij, Slobodan Dević

Abstract read
In one paragraph

Article in Zeitschrift fur medizinische Physik, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Stevan PecićFaculty of Physics, University of Belgrade, Studentski trg 12-16, Belgrade 11000, Serbia. Electronic address: stevan.pecic@ff.bg.ac.rs.
Miloš VićićFaculty of Physics, University of Belgrade, Studentski trg 12-16, Belgrade 11000, Serbia.
Ivan BelčaFaculty of Physics, University of Belgrade, Studentski trg 12-16, Belgrade 11000, Serbia.
Strahinja StojadinovićDepartment of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas 75390, TX, United States.
Borko NidžovićInstitute of Oncology and Radiology of Serbia, Pasterova 14, Belgrade 11000, Serbia.
Ljubomir KurijUniversity Clinical Center of Serbia, Center for Neurooncology, Gamma Knife, Koste Todorovića 4, Belgrade 11000, Serbia.
Slobodan DevićMedical Physics Unit, McGill University, Montreal H4A 3J1, QC, Canada; Department of Radiation Oncology, SMBD Jewish General Hospital, Montreal H3T 1E2, QC, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Reliable calibration is one of the major challenges in using radiochromic films (RCF) for radiation dosimetry. In this study the feasibility of using dose gradients produced by a physical wedge (PW) for RCF calibration was investigated. The aim was to establish an efficient and reproducible method for calibrating RCF using a PW. Film strips were used to capture the wedge dose profile for five different exposures and the acquired scans were processed to generate corresponding net optical density wedge profiles. The proposed method was compared to the benchmark calibration, following the guidelines for precise calibration using uniform dose fields. The results of the benchmark comparison presented in this paper showed that using a single film strip for measuring wedge dose profile is sufficient for estimating a reliable calibration curve within the recorded dose range. Furthermore, the PW calibration can be extrapolated or extended by using multiple gradients for the optimal coverage of the desired calibration dose range. The method outlined in this paper can be readily replicated using the equipment and expertise commonly found in a radiotherapy center. Once the dose profile and central axis attenuation coefficient of the PW are determined, they can serve as a reference for a variety of calibrations using different types and batches of film. This investigation demonstrated that the calibration curves obtained with the presented PW calibration method are within the bounds of the measurement uncertainty evaluated for the conventional uniform dose field calibration method.

Indexed as

Film DosimetryCalibrationHumansReproducibility of ResultsCalibrationDose gradientsEBT3Physical wedgeRadiochromic film dosimetry

Identifiers

PMID37393128
PMCPMC12166919

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.