Evidence map›Paper›PMID 37391531›Full record

ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2024

Development of patient-specific osteosynthesis including 3D-printed drilling guides for medial tibial plateau fracture surgery.

Nick Assink, Miriam G E Oldhoff, Kaj Ten Duis, Joep Kraeima, Job N Doornberg, Max J H Witjes, Jean-Paul P M de Vries, Anne M L Meesters, Frank F A IJpma

Open access · hybridAbstract read
In one paragraph

Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.4field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 11 citations in OpenAlex.

  1. Trial
  2. Experience with patient-specific guides, insteatientad of general surgical experience, improves the accuracy of 3D-guided corrective osteotomies.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
    Article
  3. Biomechanical Stability of Tibia Plateau Fracture Treatment: Conventional vs. Finite Element-Based Preoperative Planning.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026
    Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Advances of 3D printing technologies in orthopaedic trauma and surgical training: a transformative approach.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024
    Article
  10. 3D-assisted corrective osteotomies of the distal radius: a comparison of pre-contoured conventional implants versus patient-specific implants.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Nick AssinkDepartment of Trauma Surgery, University of Groningen, University Medical Center Groningen, HPC BA13, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands. n.assink@umcg.nl.ORCID http://orcid.org/0000-0002-0034-6816
Miriam G E OldhoffDepartment of Trauma Surgery, University of Groningen, University Medical Center Groningen, HPC BA13, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands.ORCID http://orcid.org/0000-0002-4161-3634
Kaj Ten DuisDepartment of Trauma Surgery, University of Groningen, University Medical Center Groningen, HPC BA13, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands.ORCID http://orcid.org/0000-0001-8920-8796
Joep Kraeima3D lab, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.ORCID http://orcid.org/0000-0001-8527-960X
Job N DoornbergDepartment of Trauma Surgery, University of Groningen, University Medical Center Groningen, HPC BA13, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands.ORCID http://orcid.org/0000-0002-1270-2742
Max J H Witjes3D lab, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.ORCID http://orcid.org/0000-0002-4135-3246
Jean-Paul P M de VriesDepartment of Surgery, University Medical Center Groningen, Groningen, The Netherlands.ORCID http://orcid.org/0000-0002-2669-320X
Anne M L MeestersDepartment of Trauma Surgery, University of Groningen, University Medical Center Groningen, HPC BA13, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands.ORCID http://orcid.org/0000-0001-6882-0054
Frank F A IJpmaDepartment of Trauma Surgery, University of Groningen, University Medical Center Groningen, HPC BA13, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands.ORCID http://orcid.org/0000-0002-9420-2732
University Medical Center Groningen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeA substantial proportion of conventional tibial plateau plates have a poor fit, which may result in suboptimal fracture reduction due to applied -uncontrolled- compression on the bone. This study aimed to assess whether patient-specific osteosyntheses could facilitate proper fracture reduction in medial tibial plateau fractures.

methodsIn three Thiel embalmed human cadavers, a total of six tibial plateau fractures (three Schatzker 4, and three Schatzker 6) were created and CT scans were made. A 3D surgical plan was created and a patient-specific implant was designed and fabricated for each fracture. Drilling guides that fitted on top of the customized plates were designed and 3D printed in order to assist the surgeon in positioning the plate and steering the screws in the preplanned direction. After surgery, a postoperative CT scan was obtained and outcome was compared with the preoperative planning in terms of articular reduction, plate positioning, and screw direction.

resultsA total of six patient-specific implants including 41 screws were used to operate six tibial plateau fractures. Three fractures were treated with single plating, and three fractures with dual plating. The median intra-articular gap was reduced from 6.0 (IQR 4.5-9.5) to 0.9 mm (IQR 0.2-1.4), whereas the median step-off was reduced from 4.8 (IQR 4.1-5.3) to 1.3 mm (IQR 0.9-1.5). The median Euclidean distance between the centre of gravity of the planned and actual implant was 3.0 mm (IQR: 2.8-3.7). The lengths of the screws were according to the predetermined plan. None of the screws led to screw penetration. The median difference between the planned and actual screw direction was 3.3° (IQR: 2.5-5.1).

conclusionThis feasibility study described the development and implementation of a patient-specific workflow for medial tibial plateau fracture surgery that facilitates proper fracture reduction, tibial alignment and accurately placed screws by using custom-made osteosynthesis plates with drilling guides.

Indexed as

Tibial FracturesTibial Plateau FracturesBone PlatesBone ScrewsFracture Fixation, InternalHumansPrinting, Three-Dimensional3D printingGuided surgeryMedial tibial plateauPatient-specific implantPSIThree-dimensionalTibial plateau fractureVirtual surgical planning

Identifiers

PMID37391531
PMCPMC10924019
OpenAlexW4382677533

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.