A methodology for incorporating a photon-counting CT system into routine clinical use.

Steven T Bache, Ehsan Samei

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Steven T BacheDepartment of Radiology Clinical Imaging Physics Group, Duke University Medical Center, Durham, North Carolina, USA.
Ehsan SameiCarl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina, USA.

Funding

Simulation Tools for Dynamic CTR01EB001838 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI SAMEI, EHSAN, SEGARS, WILLIAM P · 2005 to 2023
$6.9M
NIBIB NIH HHS R01 EB001838
6 · The paper itself

Abstract

Photon-counting computed tomography (PCCT) systems are increasingly available in the U.S. following Food and Drug Administration (FDA) approval of the first clinical PCCT system in Fall 2021. Consequently, there will be a need to incorporate PCCTs into existing fleets of traditional CT systems. The commissioning process of a PCCT was devised by evaluating the degree of agreement between the performance of the PCCT and that of established clinical CT systems. A PCCT system (Siemens NAEOTOM Alpha) was evaluated using the American College of Radiology(ACR) CT phantom (Gammex 464). The phantom was scanned on the system and on a 3rd Generation EID CT system (Siemens Force) at three clinical dose levels. Images were reconstructed across the range of available reconstruction kernels and Iterative Reconstruction (IR) strengths. Two image quality metrics-spatial resolution and noise texture-were calculated using AAPM TG233 software (imQuest), as well as a dose metric to achieve target image noise magnitude of 10 HU. For each pair of EID-PCCT kernel/IR strengths, the difference in metrics were calculated, weighted, and multiplied over all metrics to determine the concordance between systems. IR performance was characterized by comparing relative noise texture and reference dose as a function of IR strength for each system. In general, as kernel "sharpness" increased for each system, spatial resolution, noise spatial frequency, and reference dose increased. For a given kernel, EID reconstruction showed higher spatial resolution compared to PCCT in standard resolution mode. PCCT implementation of IR better preserved noise texture across all strengths compared to the EID, demonstrated by respective 20 and 7% shifts in noise texture from IR "Off" to IR "Max." Overall, the closest match for a given EID reconstruction kernel/IR strength was identified as a PCCT kernel with "sharpness" increased by 1 step and IR strength increased by 1-2 steps. Substantial dose reduction potential of up to 70% was found when targeting a constant noise magnitude.

Indexed as

BenchmarkingTomography, X-Ray ComputedDrug TaperingHumansPhantoms, ImagingPhotonsCT image qualityCT protocolsphoton-counting CT

Identifiers

PMID37389963
PMCPMC10402682

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.