Evidence map›Paper›PMID 37389537›Full record

Trial reportAnnals of surgery2023

Does the Use of Probe-based Near-infrared Autofluorescence Parathyroid Detection Benefit Parathyroidectomy?: A Randomized Single-center Clinical Trial.

Colleen M Kiernan, Giju Thomas, Anuradha Patel, Run Fan, Fei Ye, Parker A Willmon, Carmen C Solórzano

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Annals of surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

Colleen M KiernanDivision of Surgical Oncology and Endocrine Surgery, Vanderbilt University Medical Center, Nashville, TN.
Giju ThomasVanderbilt Biophotonics Center, Vanderbilt University, Nashville, TN.
Anuradha PatelDivision of Surgical Oncology and Endocrine Surgery, Vanderbilt University Medical Center, Nashville, TN.
Run FanDepartment of Biostatistics, Vanderbilt University, Nashville, TN.
Fei YeDepartment of Biostatistics, Vanderbilt University, Nashville, TN.
Parker A WillmonVanderbilt Biophotonics Center, Vanderbilt University, Nashville, TN.
Carmen C SolórzanoDivision of Surgical Oncology and Endocrine Surgery, Vanderbilt University Medical Center, Nashville, TN.

Funding

Academic-Industry Partnership for the Translation of a Novel Optical Imaging Approach to guide Endocrine Cancer SurgeryR01CA212147 · NCI · VANDERBILT UNIVERSITY · PI MAHADEVAN-JANSEN, ANITA · 2018 to 2022
$2.7M
NCI NIH HHS R01 CA212147
6 · The paper itself

Abstract

objectiveTo evaluate the benefits of probe-based near-infrared autofluorescence (NIRAF) parathyroid identification during parathyroidectomy.

backgroundIntraoperative parathyroid gland identification during parathyroidectomy can be challenging, while additionally requiring costly frozen sections. Earlier studies have established NIRAF detection as a reliable intraoperative adjunct for parathyroid identification.

methodsPatients undergoing parathyroidectomy for primary hyperparathyroidism were prospectively enrolled by a senior surgeon (>20 years experience) and a junior surgeon (<5 years experience), while being randomly allocated to the probe-based NIRAF or control group. Data collected included procedure type, number of parathyroids identified with high confidence by the surgeon and the resident, number of frozen sections performed, parathyroidectomy duration, and number of patients with persistent disease at the first postoperative visit.

resultsOne hundred sixty patients were randomly enrolled under both surgeons to the probe group (n=80) versus control (n=80). In the probe group, parathyroid identification rate of the senior surgeon improved significantly from 3.2 to 3.6 parathyroids per patient ( P <0.001), while that of the junior surgeon also rose significantly from 2.2 to 2.5 parathyroids per patient ( P =0.001). Parathyroid identification was even more prominent for residents increasing significantly from 0.9 to 2.9 parathyroids per patient ( P <0.001). Furthermore, there was a significant reduction in frozen sections utilized in the probe group versus control (17 vs 47, P =0.005).

conclusionProbe-based NIRAF detection can be a valuable intraoperative adjunct and educational tool for improving confidence in parathyroid gland identification, while potentially reducing the number of frozen sections required.

Indexed as

ParathyroidectomyParathyroid GlandsHumansMicrosurgeryParathyroid HormoneParathyroid Hormone

Identifiers

PMID37389537
PMCPMC10836830

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.