Evidence map›Paper›PMID 37388897›Full record

ArticleArthroscopy, sports medicine, and rehabilitation2023

Modified Lemaire Tenodesis Forces in Cadaveric Specimens Are Not Affected by Random Small-Scale Variations in the Femoral Insertion Point During Active Knee Joint Flexion-Extension.

Maximilian Sigloch, Raul Mayr, Bernhard Glodny, Christian Coppola, Romed Hoermann, Werner Schmoelz

Abstract read
In one paragraph

Article in Arthroscopy, sports medicine, and rehabilitation, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Maximilian SiglochDepartment for Orthopaedics and Traumatology, Medical University of Innsbruck, Innsbruck, Austria.
Raul MayrDepartment for Orthopaedics and Traumatology, Medical University of Innsbruck, Innsbruck, Austria.
Bernhard GlodnyDepartment of Radiology, Medical University of Innsbruck, Innsbruck, Austria.
Christian CoppolaDepartment for Orthopaedics and Traumatology, Medical University of Innsbruck, Innsbruck, Austria.
Romed HoermannInstitute for Clinical and Functional Anatomy, Medical University of Innsbruck, Innsbruck, Austria.
Werner SchmoelzDepartment for Orthopaedics and Traumatology, Medical University of Innsbruck, Innsbruck, Austria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To directly measure lateral extra-articular tenodesis (LET) forces supporting anterior cruciate ligament reconstruction (ACLR) during dynamic flexion-extension cycles induced by simulated active muscle forces, to investigate the influence of random surgical variation in the femoral LET insertion point around the target insertion position, and to determine potential changes to the extension behavior of the knee joint in a cadaveric model. Methods: After iatrogenic anterior cruciate ligament deficiency and simulated anterolateral rotatory instability, 7 fresh-frozen cadaveric knee joints were treated with isolated ACLR followed by combined ACLR-LET. The specimens were tested on a knee joint test bench during active dynamic flexion-extension with simulated muscle forces. LET forces and the degree of knee joint extension were measured. Random variation in the LET insertion point around the target insertion position was postoperatively quantified by computed tomography. Results: In extension, the median LET force increased to 39 ± 2 N (95% confidence interval [CI], 36 to 40 N). In flexion over 70°, the LET was offloaded (2 ± 1 N; 95% CI, 0 to 2 N). In this study, small-scale surgical variation in the femoral LET insertion point around the target position had a negligible effect on the graft forces measured. We detected no difference in the degree of knee joint extension after combined ACLR-LET (median, 1.0° ± 3.0°; 95% CI, -6.2° to 5.2°) in comparison with isolated ACLR (median, 1.1° ± 3.3°; 95% CI, -6.7° to 6.1°; Conclusions: LET forces in combined ACLR-LET increased to a limited extent during active knee joint flexion-extension independent of small-scale variation around 1 specific target insertion point. Combined ACLR-LET did not change knee joint extension in comparison with isolated ACLR under the testing conditions used in this biomechanical study. Clinical Relevance: Low LET forces can be expected during flexion-extension of the knee joint. Small-scale deviations in the femoral LET insertion point around the target insertion position in the modified Lemaire technique might have a minor effect on graft forces during active flexion-extension.

Identifiers

PMID37388897
PMCPMC10300583

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.