Evidence map›Paper›PMID 37388420›Full record

ArticleInternational journal of cardiology. Heart & vasculature2023

Introduction of machine perfusion of donor hearts in a single center in Germany.

Nikolaus Pizanis, Alexandros Merkourios Dimitriou, Achim Koch, Peter Luedike, Maria Papathanasiou, Tienush Rassaf, Arjang Ruhparwar, Bastian Schmack, Alexander Weymann, Katja Bettina Ferenz and 1 more

Abstract read
In one paragraph

Article in International journal of cardiology. Heart & vasculature, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. [Innovations in transplantation medicine].Innere Medizin (Heidelberg, Germany) · 2025
    Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Nikolaus PizanisUniversity Hospital Essen, West German Heart and Vascular Center, Department of Thoracic and Cardiovascular Surgery, Essen, Germany.
Alexandros Merkourios DimitriouUniversity Hospital Essen, West German Heart and Vascular Center, Department of Thoracic and Cardiovascular Surgery, Essen, Germany.
Achim KochUniversity Hospital Essen, West German Heart and Vascular Center, Department of Thoracic and Cardiovascular Surgery, Essen, Germany.
Peter LuedikeUniversity Hospital Essen, West German Heart and Vascular Center, Department of Cardiology and Vascular Medicine, Essen, Germany.
Maria PapathanasiouUniversity Hospital Essen, West German Heart and Vascular Center, Department of Cardiology and Vascular Medicine, Essen, Germany.
Tienush RassafUniversity Hospital Essen, West German Heart and Vascular Center, Department of Cardiology and Vascular Medicine, Essen, Germany.
Arjang RuhparwarUniversity Hospital Essen, West German Heart and Vascular Center, Department of Thoracic and Cardiovascular Surgery, Essen, Germany.
Bastian SchmackUniversity Hospital Essen, West German Heart and Vascular Center, Department of Thoracic and Cardiovascular Surgery, Essen, Germany.
Alexander WeymannUniversity Hospital Essen, West German Heart and Vascular Center, Department of Thoracic and Cardiovascular Surgery, Essen, Germany.
Katja Bettina FerenzUniversity Hospital Essen, Institute of Physiology, Essen, Germany.
Markus KamlerUniversity Hospital Essen, West German Heart and Vascular Center, Department of Thoracic and Cardiovascular Surgery, Essen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Organ shortage, subsequent use of extended donor criteria organs and high-risk recipients needing redo-surgery are increasing the complexity of heart transplantation. Donor organ machine perfusion (MP) is an emerging technology allowing reduction of ischemia time as well as standardized evaluation of the organ. The aim of this study was to review the introduction of MP and analyze the results of heart transplantation after MP in our center. Methods: In a retrospective single-center study, data from a prospectively collected database were analysed. From July 2018 to August 2021, fourteen hearts were retrieved and perfused using the Organ Care System (OCS), 12 hearts were transplanted. Criteria to use the OCS were based on donor/recipient characteristics. Primary objective was 30-day survival, secondary objectives were major cardiac adverse events, graft function, rejection episodes as well as overall survival in the follow-up and assessment of MP technical reliability. Results: All patients survived the procedure and the postoperative 30-day interval. No MP related complications were noted. Graft ejection fraction beyond 14 days was ≥ 50% in all cases. Endomyocardial biopsy showed excellent results with no or mild rejection. Two donor hearts were rejected after OCS perfusion and evaluation. Conclusion:

Indexed as

Donor heart evaluationEx-vivo perfusionHeart ischemic timeHeart transplantationHigh-risk heart transplant recipients

Identifiers

PMID37388420
PMCPMC10300355

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.