ArticleJournal of anesthesia, analgesia and critical care2021
Intraoperative cardiac function assessment by transesophageal echocardiography versus FloTrac/Vigileo™ system during pectus excavatum surgical repair.
Article in Journal of anesthesia, analgesia and critical care, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Application of transesophageal echocardiography combined with FloTrac monitoring in cardiac valve replacement surgery.Frontiers in cardiovascular medicine · 2025Article
- Phoenix Comprehensive Assessment of Pectus Excavatum Symptoms (PCAPES).Journal of thoracic disease · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPectus excavatum (PE), a congenital deformity of the chest wall, can lead to cardiac compression and related symptoms. PE surgical repair can improve cardiac function. Intraoperative transesophageal echocardiography (TEE) has been successfully employed to assess intraoperative hemodynamic variations in patients undergoing PE repair. FloTrac/Vigileo™ system (Edwards Life-sciences Irvine, CA) (FT/V) is a minimally invasive cardiac output monitoring system. This retrospective study aimed to assess hemodynamic changes in surgical repair of PE using FT/V and concordance with parameters measured by TEE.
resultsN=19 patients submitted to PE repair via Ravitch or Nuss technique were enrolled. Intraoperative cardiac assessments simultaneously obtained via TEE and FT/V system were investigated. The agreement between TEE-derived cardiac output (CO-TEE) and FT/V system parameter (COAP) was evaluated. The relationship between COTEE and COAP was analyzed for all data using linear regression analysis. A significant correlation between COAP and COTEE values (R = 0.65, p < 0.001) was found. Bland-Altman analysis of COAP and COTEE showed a bias of 0.13 L/min and a limit of agreement of - 2.33 to 2.58 L/min, with a percentage error of 48%. Intraoperative measurements by TEE and FT/V both showed a significant increase in CO after surgical correction of PE (p < 0.005).
conclusionsFT/V system compared to TEE in hemodynamic monitoring during PE surgery yielded clinically unacceptable results due to a high percentage error. After surgical correction of PE, CO, measured by TEE and FT/V, significantly improved.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.