Evidence map›Paper›PMID 37386388›Full record

ArticleBMC pregnancy and childbirth2023

Determining the validity of non-invasive spot-check hemoglobin co-oximetry testing to detect anemia in postpartum women at a tertiary care centre, a prospective cohort study.

Kienna Mills, Julie M Vermeer, Warren E Berry, Erwin Karreman, Christine D Lett

Abstract read
In one paragraph

Article in BMC pregnancy and childbirth, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Observational
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kienna MillsHealth Science Building, University of Saskatchewan, 107 Wiggins Rd, Saskatoon, SK, S7N 5E5, Canada.
Julie M VermeerDepartment of Obstetrics and Gynecology, University of Saskatchewan, Reginal General Hospital, 1440 14 Ave, ReginaRegina, Saskatchewan, S4P 0W5, Canada.
Warren E BerrySaskatchewan Health Authority, 2180 23rd Avenue, Regina, SK, S4S 0A5, Canada.
Erwin KarremanSaskatchewan Health Authority, 2180 23rd Avenue, Regina, SK, S4S 0A5, Canada.
Christine D LettDepartment of Obstetrics and Gynecology, University of Saskatchewan, Reginal General Hospital, 1440 14 Ave, ReginaRegina, Saskatchewan, S4P 0W5, Canada. Christine.Lett@usask.ca.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSpot-check hemoglobin co-oximetry analyzers measure hemoglobin transcutaneously and offer the benefit of a hemoglobin measurement without phlebotomy. The objective of this study was to determine the validity of non-invasive spot-check hemoglobin co-oximetry testing for the detection of postpartum anemia (hemoglobin < 10 g/dL).

methodsFive hundred eighty-four women aged 18 and over were recruited on postpartum day one following a singleton delivery. Two non-invasive spot-check hemoglobin co-oximetry monitors, Masimo Pronto Pulse CO-Oximeter (Pronto) and Masimo Rad-67 Pulse CO-Oximeter (Rad-67), were evaluated and compared to the postpartum phlebotomy hemoglobin value.

resultsOf 584 participants, 31% (181) had postpartum anemia by phlebotomy hemoglobin measurement. Bland-Altman plots determined a bias of + 2.4 (± 1.2) g/dL with the Pronto and + 2.2 (± 1.1) g/dL with the Rad-67. Low sensitivity was observed: 15% for the Pronto and 16% for the Rad-67. Adjusting for the fixed bias, the Pronto demonstrated a sensitivity of 68% and specificity of 84%, while the Rad-67 demonstrated a sensitivity of 78% and specificity of 88%.

conclusionA consistent overestimation of hemoglobin by the non-invasive spot-check hemoglobin co-oximetry monitors compared to phlebotomy hemoglobin result was observed. Even after adjusting for the fixed bias, the sensitivity for detecting postpartum anemia was low. Detection of postpartum anemia should not be based on these devices alone.

Indexed as

AnemiaPuerperal DisordersAdolescentAdultFemaleHumansOximetryPostpartum PeriodProspective StudiesTertiary Care CentersAnemiaNon-invasive hemoglobin measurementPatient blood managementPostpartumSpot-check hemoglobin co-oximetry

Identifiers

PMID37386388
PMCPMC10308759

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.