Evidence map›Paper›PMID 37386116›Full record

ArticleScientific reports2023

Structural analysis of customized 3D printed plate for pelvic bone by comparison with conventional plate based on bending process.

Woo-Lam Jo, Yang-Guk Chung, Seung-Han Shin, Jae-Hak Lim, Moo-Sub Kim, Do-Kun Yoon

Erratum issuedAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Woo-Lam JoDepartment of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, 222, Banpo-Daero, Seocho-Gu, Korea.
Yang-Guk ChungDepartment of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, 222, Banpo-Daero, Seocho-Gu, Korea. ygchung@catholic.ac.kr.
Seung-Han ShinDepartment of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, 222, Banpo-Daero, Seocho-Gu, Korea.
Jae-Hak LimDepartment of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, 222, Banpo-Daero, Seocho-Gu, Korea.
Moo-Sub KimIndustrial R&D Center, KAVILAB Co. Ltd., 06693, Seoul, Republic of Korea.
Do-Kun YoonIndustrial R&D Center, KAVILAB Co. Ltd., 06693, Seoul, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Pelvic bone fracture is highly complex, and its anatomical reduction is difficult. Therefore, patient-specific customized plates have been developed using three-dimensional (3D) printing technology and are being increasingly used. In this study, the reduction status in five representative pelvic fracture models was compared between two groups: the 3D printing plate (3DP) group using a patient-specific 3D printed plate after virtual reduction and the conventional plate (CP) group using a conventional plate by manual bending. The 3DP and CP groups included 10 and 5 cases, respectively. The fractured models were reduced virtually and their non-locking metal plates were customized using 3D printing. The process of contouring the conventional plates to fit the contact surface of the bone with the bending tool was conducted by an experienced pelvic bone trauma surgeon. The reduction and fixation achieved using the two different plate groups was compared, and the significance of differences in the results was analyzed using paired t-tests, after verifying the normality of data distribution. The vertex distances between the surface of the bone and the contact surface of the plate were significantly lower in the 3DP group than in the CP group (0.407 ± 0.342 and 2.195 ± 1.643, respectively, P = 0.008). Length and angular variations, which are measurements of the reduction state, were also lower in the 3DP group than in the CP group (length variation: 3.211 ± 2.497 and 5.493 ± 3.609, respectively, P = 0.051; angular variation: 2.958 ± 1.977 and 4.352 ± 1.947, respectively, P = 0.037). The customized 3D printed plate in the virtual reduction model provided a highly accurate reduction of pelvic bone fractures, suggesting that the customized 3D printed plate may help ensure easy and accurate reduction.

Indexed as

Fractures, BonePelvic BonesPlastic Surgery ProceduresBone PlatesHumansPrinting, Three-DimensionalPsychotherapy

Identifiers

PMID37386116
PMCPMC10310805

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.