ArticleFrontiers in surgery2023
Robot-assisted radical cystectomy with intracorporeal reconstruction of urinary diversion by mechanical stapler: prospective evaluation of early and late complications.
Article in Frontiers in surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 10 citations in OpenAlex.
- Effectiveness of bedside staplers in bariatric robotic procedures.Surgical endoscopy · 2024Article
- Feasibility and safety of laparoscopic radical cystectomy for male octogenarians with muscle-invasive bladder cancer.BMC cancer · 2024Article
- Intracorporeal urinary diversion offers the advantage of delaying postoperative renal function injury in patients undergoing robot-assisted radical cystectomy.Frontiers in oncology · 2024Article
- Editorial: History, advantages, complications, and limits of minimally invasive urologic pelvic surgery.Frontiers in surgery · 2023Article
- Improving safety in the performance of robotic urinary diversions: a narrative review.Therapeutic advances in urologyReview
- Intracorporeal ileal conduit versus orthotopic neobladder after robotic radical cystectomy: A systematic review and meta-analysis of complications and perioperative outcomes.Indian journal of urology : IJU : journal of the Urological Society of IndiaReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Radical cystectomy with pelvic lymph node dissection is the gold standard treatment for non-metastatic muscle-invasive bladder cancer and high-risk non-muscle-invasive bladder cancer. For years, the traditional open surgery approach was the only viable option. The widespread of robotic surgery led to its employment also in radical cystectomy to reduce complication rates and improve functional outcomes. Regardless of the type of approach, radical cystectomy is a procedure with high morbidity and not negligible mortality. Data available in the literature show how the use of staplers can offer valid functional outcomes, with an acceptable rate of complications shortening the operative time. The aim of our study was to describe the perioperative outcomes and complications associated with robot-assisted radical cystectomy (RARC) with intracorporeal urinary diversion (ICUD) using a mechanical stapler. Material and methods: From January 2015 to May 2021, we enrolled patients who underwent RARC with pelvic node dissection and stapled ICUD (ileal conduit or ileal Y-shaped neobladder according to the Perugia ileal neobladder) in our high-volume center. Demographic features, perioperative outcomes and early (≤30 days) and late (>90 days) post-operative complications according to the Clavien-Dindo classification, were recorded for each patient. We also analyzed the potential linear correlation between demographic, pre-operative as well as operative features and the risk of post-operative complications. Results: Overall, 112 patients who underwent RARC with ICUD were included with a minimum follow-up of 12 months. Intracorporeal Perugia ileal neobladder was performed in 74.1% of cases while ileal conduit was performed in 25.9%. The mean operative time, estimated intraoperative blood loss, and LOS were 289.1 ± 59.7 min, 390.6 ± 186.2 ml, and 17.5 ± 9.8 days, respectively. Early minor and major complications accounted for 26.7% and 10.8%, respectively. Overall late complications were 40.2%. The late most common complications were hydronephrosis (11.6%) and urinary tract infections (20.5%). Stone reservoir formation occurred in 2.7% of patients. Major complications occurred in 5.4%. In the sub-analysis, the mean operative time and the estimated blood loss improved significantly from the first 56 procedures to the last ones. Conclusion: RARC with ICUD performed by mechanical stapler is a safe and effective technique. Stapled Y-shaped neobladder did not increase the complication rate.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.