Evidence map›Paper›PMID 37380707›Full record

ArticleScientific reports2023

iMPI: portable human-sized magnetic particle imaging scanner for real-time endovascular interventions.

P Vogel, M A Rückert, C Greiner, J Günther, T Reichl, T Kampf, T A Bley, V C Behr, S Herz

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
6.4field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 58 citations in OpenAlex.

  1. Verification and validation in canine cadaver of an MPI-integrable RF head coil for magnetic particle hyperthermia.International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Therapeutic mRNA vaccine applications in oncology.Molecular therapy : the journal of the American Society of Gene Therapy · 2025
    Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Machine Learning and Deep Learning Applications in Magnetic Particle Imaging.Journal of magnetic resonance imaging : JMRI · 2025
    Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

P VogelDepartment of Experimental Physics 5 (Biophysics), Julius-Maximilians-University Würzburg, Würzburg, Germany. Patrick.Vogel@physik.uni-wuerzburg.de.
M A RückertDepartment of Experimental Physics 5 (Biophysics), Julius-Maximilians-University Würzburg, Würzburg, Germany.
C GreinerDepartment of Experimental Physics 5 (Biophysics), Julius-Maximilians-University Würzburg, Würzburg, Germany.
J GüntherDepartment of Experimental Physics 5 (Biophysics), Julius-Maximilians-University Würzburg, Würzburg, Germany.
T ReichlDepartment of Experimental Physics 5 (Biophysics), Julius-Maximilians-University Würzburg, Würzburg, Germany.
T KampfDepartment of Experimental Physics 5 (Biophysics), Julius-Maximilians-University Würzburg, Würzburg, Germany.
T A BleyDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
V C BehrDepartment of Experimental Physics 5 (Biophysics), Julius-Maximilians-University Würzburg, Würzburg, Germany.
S HerzDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.
University of Würzburg · DEUniversitätsklinikum Würzburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Minimally invasive endovascular interventions have become an important tool for the treatment of cardiovascular diseases such as ischemic heart disease, peripheral artery disease, and stroke. X-ray fluoroscopy and digital subtraction angiography are used to precisely guide these procedures, but they are associated with radiation exposure for patients and clinical staff. Magnetic Particle Imaging (MPI) is an emerging imaging technology using time-varying magnetic fields combined with magnetic nanoparticle tracers for fast and highly sensitive imaging. In recent years, basic experiments have shown that MPI has great potential for cardiovascular applications. However, commercially available MPI scanners were too large and expensive and had a small field of view (FOV) designed for rodents, which limited further translational research. The first human-sized MPI scanner designed specifically for brain imaging showed promising results but had limitations in gradient strength, acquisition time and portability. Here, we present a portable interventional MPI (iMPI) system dedicated for real-time endovascular interventions free of ionizing radiation. It uses a novel field generator approach with a very large FOV and an application-oriented open design enabling hybrid approaches with conventional X-ray-based angiography. The feasibility of a real-time iMPI-guided percutaneous transluminal angioplasty (PTA) is shown in a realistic dynamic human-sized leg model.

Indexed as

AngioplastyPeripheral Arterial DiseaseAngiography, Digital SubtractionBrainHumansMagnetic Fields

Identifiers

PMID37380707
PMCPMC10307843
OpenAlexW4382398268

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked