Evidence map›Paper›PMID 37379467›Full record

ArticleMagnetic resonance in medicine2023

Feasibility of online non-rigid motion correction for high-resolution supine breast MRI.

Karyna Isaieva, Camille Meullenet, Pierre-André Vuissoz, Marc Fauvel, Lena Nohava, Elmar Laistler, Mohamed Aziz Zeroual, Philippe Henrot, Jacques Felblinger, Freddy Odille

Registry-linked trialOpen access · hybridAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02887053 (Développement Méthodologique de l'Imagerie Par Résonance Magnétique), which is not on this map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02887053 nacompletednot on this map

Développement Méthodologique de l'Imagerie Par Résonance Magnétique (IRM)

TypeinterventionalSponsorCentral Hospital, Nancy, FranceRan2008 to 2022Enrolled1,807ConditionsHealthy SubjectsArmsMRI
3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 2 countries.

Karyna IsaievaIADI, Université de Lorraine, INSERM U1254, Nancy, France.ORCID 0000-0003-1492-2244
Camille MeullenetInstitut de Cancérologie de Lorraine Alexis Vautrin, Vandoeuvre-les-Nancy, France.
Pierre-André VuissozIADI, Université de Lorraine, INSERM U1254, Nancy, France.
Marc FauvelCIC-IT 1433, INSERM, CHRU de Nancy, Nancy, France.
Lena NohavaHigh Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Elmar LaistlerHigh Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.ORCID 0000-0002-8344-8307
Mohamed Aziz ZeroualIADI, Université de Lorraine, INSERM U1254, Nancy, France.
Philippe HenrotInstitut de Cancérologie de Lorraine Alexis Vautrin, Vandoeuvre-les-Nancy, France.
Jacques FelblingerIADI, Université de Lorraine, INSERM U1254, Nancy, France.
Freddy OdilleIADI, Université de Lorraine, INSERM U1254, Nancy, France.ORCID 0000-0001-5260-8905
Inserm · FRInstitut de Cancérologie de Lorraine · FRMedical University of Vienna · AT

Funding

Austrian Science Fund FWF I 3618
6 · The paper itself

Abstract

purposeConventional breast MRI is performed in the prone position with a dedicated coil. This allows high-resolution images without breast motion, but the patient position is inconsistent with that of other breast imaging modalities or interventions. Supine breast MRI may be an interesting alternative, but respiratory motion becomes an issue. Motion correction methods have typically been performed offline, for instance, the corrected images were not directly accessible from the scanner console. In this work, we seek to show the feasibility of a fast, online, motion-corrected reconstruction integrated into the clinical workflow.

methodsFully sampled T

resultsOnline reconstruction time was 2 to 2.5 min. The metrics and the scores related to the motion artifacts significantly improved for both T

conclusionThe proposed online algorithm allows a noticeable reduction of motion artifacts and an improvement of the diagnostic quality for supine breast imaging with a clinically acceptable reconstruction time. These findings serve as a starting point for further development aimed at improving the quality of T

Indexed as

Magnetic Resonance ImagingRespirationArtifactsFeasibility StudiesHumansImage Processing, Computer-AssistedMotionbreast MRImotion correctiononline reconstruction

Identifiers

PMID37379467
PMCPMC10953366
OpenAlexW4382360793

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.