Evidence map›Paper›PMID 37379313›Full record

ArticlePLOS global public health2023

The plasma separation card as a novel solution for enhancing central laboratory capability for HIV-1 viral load monitoring in limited-access settings.

Charles Kiyaga, Caroline Makoha, Ivan Nkugwa, Christopher Okiira, Richard Okwir, Sirak Zenebe Gebreab, Patricia Rodriguez-Ventosa Suarez, Benjamin LaBrot, Ana Carrasco Durán

Abstract read
In one paragraph

Article in PLOS global public health, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Dried Spot Paradigm: Problems and Prospects in Proteomics.International journal of molecular sciences · 2025
    Review
  6. Clinical evaluation of patterned dried plasma spot cards to support quantification of HIV viral load and reflexive genotyping.Proceedings of the National Academy of Sciences of the United States of America · 2025
    Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Charles KiyagaUganda National Health Laboratory Services, Kampala, Uganda.
Caroline MakohaUganda National Health Laboratory Services, Kampala, Uganda.
Ivan NkugwaUganda National Health Laboratory Services, Kampala, Uganda.
Christopher OkiiraUganda National Health Laboratory Services, Kampala, Uganda.
Richard OkwirKisenyi Health Center IV, Kampala, Uganda.
Sirak Zenebe GebreabRoche Diagnostics International AG, Rotkreuz, Switzerland.ORCID https://orcid.org/0000-0001-5849-075X
Patricia Rodriguez-Ventosa SuarezRoche Diagnostics International AG, Rotkreuz, Switzerland.
Benjamin LaBrotRoche Molecular Systems, Pleasanton, CA, United States of America.
Ana Carrasco DuránRoche Diagnostics International AG, Rotkreuz, Switzerland.ORCID https://orcid.org/0000-0002-3070-0951

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Measurement of HIV-1 viral load (VL) is essential for monitoring antiretroviral treatment (ART) efficacy. The preferred specimen type for VL is plasma, but in remote settings where collection and preservation of plasma many not be possible, dried blood spots (DBS) are often used instead. A new specimen collection matrix, the cobas plasma separation card (PSC, Roche Diagnostics Solutions), enables specimen preparation from a finger prick or venous blood, using a multi-layer absorption and filtration design that results in a specimen similar to dried plasma. We sought to confirm the correlation between VL results obtained using PSC prepared from venous blood to those from plasma or DBS, as well as PSC prepared with capillary blood from a finger prick. PSC, DBS and plasma were prepared with blood from HIV-1 infected persons attending a primary care clinic in Kampala, Uganda. VL in PSC and plasma was measured using cobas HIV-1 (Roche Diagnostics), while VL in DBS was measured with RealTime HIV-1 (Abbott Diagnostics). The correlation between VL from plasma and PSC made from capillary or venous blood was high (regression coefficient of determination r2 between 0.87 and 0.91), and there was good agreement based on mean bias (-0.14 to 0.24 log10 copies/mL) and classification of VL above or below 1000 copies/mL (91.4% agreement). In contrast, VL from DBS was lower than plasma or PSC (mean bias 0.51 to 0.63 log10 copies/mL) and not as well correlated (r2 0.78 to 0.81, 75.1-80.5% agreement). These results confirm the utility of PSC as an alternative specimen type for HIV-1 viral load measurement in areas where preparation and optimal storage or shipment of plasma is an obstacle to provision of treatment and care of HIV-1 infected people.

Identifiers

PMID37379313
PMCPMC10306227

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.