ArticlePLOS global public health2023
The plasma separation card as a novel solution for enhancing central laboratory capability for HIV-1 viral load monitoring in limited-access settings.
Article in PLOS global public health, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Detection of Viral Nucleic Acid in Specimens Spotted on Commercial Filter Papers: A Review and Meta-Analysis.Viruses · 2026Pooled it
- Performance of plasma separation cards for HIV drug-resistance genotyping in a resource-limited setting: comparison with plasma samples.The Journal of antimicrobial chemotherapy · 2026Article
- HCV RNA quantification using the Cobas Plasma Separation Card as an alternative to EDTA plasma: a prospective multicenter study.Scientific reports · 2026Article
- Dried Blood Spots and Plasma Separation Cards can Broaden Access to Molecular Testing for HBV, HCV and HIV.Reviews in medical virology · 2025Review
- Dried Spot Paradigm: Problems and Prospects in Proteomics.International journal of molecular sciences · 2025Review
- Clinical evaluation of patterned dried plasma spot cards to support quantification of HIV viral load and reflexive genotyping.Proceedings of the National Academy of Sciences of the United States of America · 2025Article
- Article
- Assessment of the performance of the plasma separation card for HIV-1 viral load monitoring in South Africa.Journal of clinical microbiology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Measurement of HIV-1 viral load (VL) is essential for monitoring antiretroviral treatment (ART) efficacy. The preferred specimen type for VL is plasma, but in remote settings where collection and preservation of plasma many not be possible, dried blood spots (DBS) are often used instead. A new specimen collection matrix, the cobas plasma separation card (PSC, Roche Diagnostics Solutions), enables specimen preparation from a finger prick or venous blood, using a multi-layer absorption and filtration design that results in a specimen similar to dried plasma. We sought to confirm the correlation between VL results obtained using PSC prepared from venous blood to those from plasma or DBS, as well as PSC prepared with capillary blood from a finger prick. PSC, DBS and plasma were prepared with blood from HIV-1 infected persons attending a primary care clinic in Kampala, Uganda. VL in PSC and plasma was measured using cobas HIV-1 (Roche Diagnostics), while VL in DBS was measured with RealTime HIV-1 (Abbott Diagnostics). The correlation between VL from plasma and PSC made from capillary or venous blood was high (regression coefficient of determination r2 between 0.87 and 0.91), and there was good agreement based on mean bias (-0.14 to 0.24 log10 copies/mL) and classification of VL above or below 1000 copies/mL (91.4% agreement). In contrast, VL from DBS was lower than plasma or PSC (mean bias 0.51 to 0.63 log10 copies/mL) and not as well correlated (r2 0.78 to 0.81, 75.1-80.5% agreement). These results confirm the utility of PSC as an alternative specimen type for HIV-1 viral load measurement in areas where preparation and optimal storage or shipment of plasma is an obstacle to provision of treatment and care of HIV-1 infected people.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.