Evidence map›Paper›PMID 37378439›Full record

ArticleThe journal of extra-corporeal technology2023

Turbulence in surgical suction heads as detected by MRI.

Gunnar Hanekop, Jost M Kollmeier, Jens Frahm, Ireneusz Iwanowski, Sepideh Khabbazzadeh, Ingo Kutschka, Theodor Tirilomis, Christian Ulrich, Martin G Friedrich

Open access · diamondAbstract read
In one paragraph

Article in The journal of extra-corporeal technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 66% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 2 countries.

Gunnar HanekopDepartment of Anesthesiology, Intensive Care, Emergency Medicine, Pain Therapy, University Medicine, Georg-August-University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany.
Jost M KollmeierMax-Planck-Institute for Multidisciplinary Sciences, Am Faßberg 11, 37077 Goettingen, Germany.
Jens FrahmMax-Planck-Institute for Multidisciplinary Sciences, Am Faßberg 11, 37077 Goettingen, Germany.ORCID 0000-0002-8279-884X
Ireneusz IwanowskiDepartment of Heart-Thoracic- and Vascular-Surgery, University Medicine, Georg-August-University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany.
Sepideh KhabbazzadehDepartment of Anesthesiology, Intensive Care, Emergency Medicine, Pain Therapy, University Medicine, Georg-August-University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany.
Ingo KutschkaDepartment of Heart-Thoracic- and Vascular-Surgery, University Medicine, Georg-August-University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany.
Theodor TirilomisDepartment of Heart-Thoracic- and Vascular-Surgery, University Medicine, Georg-August-University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany.
Christian UlrichDepartment of Heart-Thoracic- and Vascular-Surgery, University Medicine, Georg-August-University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany.
Martin G FriedrichDepartment of Heart-Thoracic- and Vascular-Surgery, University Medicine, Georg-August-University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany.ORCID 0000-0003-4436-1919
University of Göttingen · DETissue Dynamics (Israel) · IL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBlood loss is common during surgical procedures, especially in open cardiac surgery. Allogenic blood transfusion is associated with increased morbidity and mortality. Blood conservation programs in cardiac surgery recommend re-transfusion of shed blood directly or after processing, as this decreases transfusion rates of allogenic blood. But aspiration of blood from the wound area is often associated with increased hemolysis, due to flow induced forces, mainly through development of turbulence.

methodsWe evaluated magnetic resonance imaging (MRI) as a qualitative tool for detection of turbulence. MRI is sensitive to flow; this study uses velocity-compensated T1-weighted 3D MRI for turbulence detection in four geometrically different cardiotomy suction heads under comparable flow conditions (0-1250 mL/min).

resultsOur standard control suction head Model A showed pronounced signs of turbulence at all flow rates measured, while turbulence was only detectable in our modified Models 1-3 at higher flow rates (Models 1 and 3) or not at all (Model 2).

conclusionsThe comparison of flow performance of surgical suction heads with different geometries via acceleration-sensitized 3D MRI revealed significant differences in turbulence development between our standard control Model A and the modified alternatives (Models 1-3). As flow conditions during measurement have been comparable, the specific geometry of the respective suction heads must have been the main factor responsible. The underlying mechanisms and causative factors can only be speculated about, but as other investigations have shown, hemolytic activity is positively associated with degree of turbulence. The turbulence data measured in this study correlate with data from other investigations about hemolysis induced by surgical suction heads. The experimental MRI technique used showed added value for further elucidating the underlying physical phenomena causing blood damage due to non-physiological flow.

Indexed as

Cardiac Surgical ProceduresHemolysisBlood Transfusion, AutologousHumansMagnetic Resonance ImagingSuctionBlood damageHemolysisMagnetic Resonance ImagingSuctionTurbulence

Identifiers

PMID37378439
PMCPMC10304939
OpenAlexW4378976586

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.