Evidence map›Paper›PMID 37378222›Full record

ArticleCureus2023

Mandibular Flexure and Crestal Bone Stress Distribution on an Implant-Supported Fixed Full Arch Mandibular Prosthesis: Finite Element Analysis in Three Dimensions.

Suraj Sharma, Shashikala Jain, Himanshu Gupta, Sai Govind Gavara, Pratibha Panwar, Ramanjeet Kaur Grover

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 91% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Suraj SharmaDepartment of Prosthodontics, Crown and Bridge and Oral Implantology, Maharaja Ganga Singh Dental College and Research Centre, Sri Ganganagar, IND.
Shashikala JainDepartment of Prosthodontics, Crown and Bridge and Oral Implantology, Maharaja Ganga Singh Dental College and Research Centre, Sri Ganganagar, IND.
Himanshu GuptaDepartment of Prosthodontics, Crown and Bridge and Oral Implantology, Maharaja Ganga Singh Dental College and Research Centre, Sri Ganganagar, IND.
Sai Govind GavaraDepartment of Prosthodontics, Crown and Bridge and Oral Implantology, Maharaja Ganga Singh Dental College and Research Centre, Sri Ganganagar, IND.
Pratibha PanwarDepartment of Prosthodontics, Crown and Bridge and Oral Implantology, Maharaja Ganga Singh Dental College and Research Centre, Sri Ganganagar, IND.
Ramanjeet Kaur GroverDepartment of Prosthodontics, Crown and Bridge and Oral Implantology, Maharaja Ganga Singh Dental College and Research Centre, Sri Ganganagar, IND.
Mahatma Gandhi Dental College & Hospital · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim This study's objective was to assess and analyze, using 3D Finite Element Analysis, the impact of four mandibular complete arch superstructures on the distribution of stress in the crestal bone during mandibular flexure. Materials and methods Four Finite element models of the mandible with different implant-retained framework designs have been developed. Three of these models had six axial implants placed at intervals of 11.8 mm, 18.8 mm and 25.8 mm from the midline, respectively. One model had two tilted implants and four axial implants splinted with a single piece of framework at intervals of 8.4 mm, 13.4 mm and 18.4 mm from the midline. For analyzing the stress distribution, the finished product was transferred to ANSYS R 18.1 software (Sirsa, Haryana, India) for finite element simulation, the models were constructed, the ends were restrained, and bilateral vertical loads of 50N, 100N and 150N were applied to the distal part of the framework. Results Bilateral loads were applied to each of the four 3D FEM and after assessment of Von Mises Stress and Total Deformation, a finding was made that the model with six axial implants supported by a single piece of framework underwent the highest total deformation and the model with four axial implants and two implants with distal tilts displayed most significant Von Mises stress. Conclusion Within the constraints of this 3D FEA, it was determined that mandibular flexure and peri-implant bone stress were affected by the way the framework is divided and the nature of mandibular movement. The three types of frames with the least bone stress are demonstrated by the mandibular deformation that results from two-piece frameworks on axial implants. Regardless of the number of implants, the single framework splinted with six implants shows a flexure in mandible with the highest bone stress around the implant irrespective of the angulation of the implant. Clinical significance When it comes to edentulous jaws, reducing stress in implant-supported restorative systems at varying degrees of the bone and implant interfaces and superstructures of prosthetics is one of the fundamental goals of implant treatment. A framework with proper design and a low modulus of elasticity reduces mechanical risk. Additionally, a larger number of implants helps to prevent cantilevers and spacing between the implants.

Indexed as

3d feamandibular flexuretilted implantstotal deformationvon mises stress

Identifiers

PMID37378222
PMCPMC10292118
OpenAlexW4377292545

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.