Evidence map›Paper›PMID 37376868›Full record

Trial reportJournal of applied clinical medical physics2023

Multicenter, dual fractionation scheme, single core lab comparison of rectal volume dose reduction following injection of two biodegradable perirectal spacers.

Michael Kos, Rizwan Nurani, Paulo Costa, Mateuzs Dabkowski, Joana Vale Ferreira da Silva, Shawn Zimberg, John Keane

Open access · goldAbstract readClinical TrialMulticenter Study
In one paragraph

Trial report in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 3 countries.

Michael KosNorthern NV Radiation Oncology, Spokane, Washington, USA.ORCID https://orcid.org/0000-0003-0059-4913
Rizwan NuraniWestern Radiation Oncology, Campbell, California, USA.
Paulo CostaCUF Porto Instituto, Rua Fonte das Sete Bicas, Porto, Portugal.
Mateuzs DabkowskiOnology Center - Institute of Maria Skłodowska - Curie, Warsaw, Poland.
Joana Vale Ferreira da SilvaCUF Porto Instituto, Rua Fonte das Sete Bicas, Porto, Portugal.
Shawn ZimbergAdvanced Radiation Centers of New York, Lake Success, New York, USA.
John KeaneAdvanced Radiation Centers of New York, Lake Success, New York, USA.
Advanced Radiation Centers of New York · USCUF Porto Hospital · PTCampbell Institute · USCommunity Frameworks · USThe Maria Sklodowska-Curie National Research Institute of Oncology · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeA multicenter, double-arm, central core lab, retrospective study was performed to compare the rectal dosimetry of patients implanted with two injectable, biodegradable perirectal spacers, in conventional fractionation (CF), as well as ultrahypofractionation (UH) treatment plans. METHODS AND MATERIALS: Fifty-nine patients were enrolled into the study in five centers: two centers in Europe, which implanted a biodegradable balloon spacer in a total of 24 subjects and three centers in the US, which implanted the SpaceOAR in 35 subjects. Anonymized CTs (pre and post-implantation) were reviewed by the central core lab. For VMAT CF plans rectal V50, V60, V70, and V80 were calculated. For UH plans, a corresponding rectal V22.6, V27.1, V31.37, and V36.25 were established representing 62.5%, 75%, 87.5%, and 100% of the 36.25 Gy prescribed dose.

resultsFor CF VMAT, a comparison between the balloon spacer and the SpaceOAR revealed a significant difference of 33.4% decrease in mean rectal V50 (71.9% vs. 38.5%, p < 0.001), 27.7% in mean rectal V60 (79.6% vs. 51.9%, p < 0.001), 17.1% difference in mean rectal V70 (84.1% vs. 67.0%, p = 0.001), and a significant difference of 3.0% (p = 0.019) in mean rectal V80 (87.2% vs. 84.2%). With UH analysis, the mean rectal dose reduction for the balloon spacer compared to the SpaceOAR was 79.2% and 53.3% for V27.1 (p < 0.001), 84.1% and 68.1% for V31.71 (p = 0.001), and 89.7% and 84.8% for V36.25 (p = 0.012), respectively.

conclusionRectal dosimetry is more favorable for treatment with the balloon spacer compared with SpaceOAR. Further research, particularly in the context of a prospective randomized clinical trial design, is needed to assess the acute and late toxicity experience as well as physician satisfaction with achieving symmetrical implantation, and ease of use in light of increasing clinical use.

Indexed as

Drug TaperingRectumAzo CompoundsHumansNitrilesRadiotherapy DosageRetrospective StudiesAzo CompoundsNitrilesV 70balloon spacerorgan at riskperirectal spacerprostate cancerSBRTultra hypofractionationVMAT

Identifiers

PMID37376868
PMCPMC10562021
OpenAlexW4382345016

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.